4.2 Car Park Layout
Table 4.2 identifies the characteristics of the proposed car parking area with respect to Noosa Councils
Requirements. The car park layout is to be designed in accordance Australian Standard AS2890.1. The last
column identifies the compliance of each design aspect.

Table 4.2: Parking Design Requirements

   Design Aspect                       AS2890.1 Requirement          Proposed Provision            Compliance
   Parking space length:
        − Standard Space               5.4m                          5.4m                          Compliant
        − PWD Space                    5.4m                          5.4m                          Compliant
        − Parallel bays                5.9m                          5.9m – 6.2m                   Compliant
   Parking space width:
        − Staff                        2.4m                          2.4m                          Compliant
        −   Visitor                    2.6m                          2.6m                          Compliant
        −   PWD Space                  2.4m + 2.4m ‘Shared Area’     2.4m + 2.4m ‘Shared Area’     Compliant
        −   Clearance to obstruction   0.3m                          0.3m                          Compliant
        −   Parallel bays              2.1m                          2.1m                          Compliant

   Aisle Width:
        − Staff                        5.8m                          5.8m – 6.2m                   Compliant
        − Visitor                      5.8m                          5.8m – 6.2m                   Compliant

   Parking envelope clearance          Space 0.3m clear of wall or   Space 0.3m clear of wall or   Compliant
                                       large columns                 large columns
   Maximum Gradient:
       − PWD parking                   1:40 (2.5%)                   Flat                          Compliant
       − Parking bay                   1:20 (5.0%)                   Flat                          Compliant
       − Parking aisle                 1:16 (6.25%)                  1:20 (5%)                     Compliant
   Height clearance:
       − General Min                   2.2m (2.5m PWD)               4.25m                         Compliant



The development proposal complies with ‘AS2890.1’ requirements.




Site: Lot 2 Noosa Civic, Noosaville                                                                             12
Reference: 21BRT0259

Used in these records

About this file

File size
4.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Traffic Report.pdf · 4.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.