230324 - 47 Tablelands Road, COORAN - Engineering Plans
Plans and drawings: the text below has words only, no drawings.
50mm Step
BALCONY / VERANDAH FLOOR < 1000mm ABOVE GROUND 1 x 10/16x16 Wafer
Screw Through Bearer
MAXIMUM POST and Joist Typ.
WIDTH W JOIST BEARER A BEARER B Joist Typ.
CENTRES
2400 150C12 150NC24 NA 3200mm JOIST
1 x M12x35 High Tensile Bolt (Class 8.8)
@ 450 Centres Max Staggered
2700 150C12 150NC24 NA 3200mm
3000 150C15 150NC24 NA 3200mm
Section 1 1 x M12x35 High Tensile Bolt (Class 8.8)
Verandah Nesting
3600 200C15 200NC24 NA 3200mm @ Joist positions 450 Centres Max
Channel
2 x 12/14x20 Teks Per Joist
4000 150C12 150NC24 200C15 3200mm Typ.
6000 150C15 150NC24 200C24 3200mm
VERANDAH BEARER CONNECTION DETAIL <1m VERANDAH STEP DOWN DETAIL <1m
BALCONY / VERANDAH FLOOR > 1000mm and < 3000mm ABOVE GROUND
50mm Step
WIDTH W JOIST BEARER A BEARER B MAXIMUM POST 1 x 10/16x16 Wafer
CENTRES 2 x 14/20 Teks Screw Through Bearer
@ 450 Centres Max Staggered and Joist Typ.
2400 150C12 150NC24 NA 3200mm Joist Typ.
2700 150C15 150NC24 NA 3200mm JOIST
1 x M12x35 High Tensile Bolt (Class 8.8)
3000 150C15 150NC24 NA 3200mm @ 900 Centres Max Staggered
2 x 14/20 Teks
3600 200C15 200NC24 NA 3200mm @ 900 Centres Max Staggered
Section 1 1 x M12x35 High Tensile Bolt (Class 8.8)
Verandah Nesting
4000 150C12 150NC24 200C15 3200mm Channel
@ 900 Centres Max Staggered
2 x 12/14x20 Teks Per Joist
6000 150C15 150NC24 200C24 3200mm Typ.
REFER TO PAGE 1 FOR MAIN FLOOR DETAILS
VERANDAH BEARER CONNECTION DETAIL >1m VERANDAH STEP DOWN DETAIL >1m
NOTES
FLOOR SYSTEM IS DESIGN TO AS1170.1 FOR A LIVE
LOAD OF 1.5 kPa FOR FLOORS LESS THAN 1000mm JOISTS @ 450 CTRS JOISTS @ 450 CTRS
ABOVE GROUND AND 2.0 kPa FOR FLOORS GREATER
THAN 1000mm ABOVE GROUND
MINIMUM BEARING CAPACITY OF GROUND - 100KPa
Post Centre
Post Centre
LIMIT STATE DESIGN HAS BEEN USED
MAX POST HEIGHT 3000 mm
LOAD BEARING WALLS MUST BE BOLTED TO JOIST OR
BEARER
DESIGNED IN ACCORDANCE WITH AS1170.0, AS1170.1,
Post Centre
Post Centre
AS1170.2, AS4100, AS4600
Length
Length
Post Centre
Post Centre
4 x 14/20 TEKS TO
0.75 ANGLE WITH 2 x 12/14 BEAM
TEKS PER CONNECTION or 2 x M12 purlin bolts
100 WIDE x 6 PLATE
Post Centre
Post Centre
WELDED TO POST
VERANDAH VERANDAH
JOIST TO CENTRE BEARER
DROP DOWN BEARER TO POST SPAN SPAN
CONNECTION
CONNECTION
TYPICAL VERANDAH TYPICAL VERANDAH FLOOR LAYOUT
FLOOR LAYOUT WITH BEARER B
Mr Vic Bacud, Jnr
MIEAust CPEng EC 26331 5 Pronger Parade DATE : 26/09/2022
Standard
Mecano
NPER-3 Gympie Industrial Estate
Registered on the NPER-3 in the Category of Po Box 758 Balcony / Verandah DES SHEET 2 OF 2
Civil and Structural Gympie Qld 4570 Floor Engineering
National Professional Engineers Register Section Three Sheds Pty Ltd DRWN SY DWG. NO.
Ph (07) 5482 5614
COPYRIGHT: Email - [email protected] CHK VB FRAME ENGINEERING
REV.