230324 - 47 Tablelands Road, COORAN - Engineering Plans
Plans and drawings: the text below has words only, no drawings.
Sub Floor Bracing
set to site measure
4 x 14/20 teks to post
M16 A
nch or Rod
Nut
Poured in one monolithic
Nut
Fall Fall
Depth as per Engineering Report
Note:
1. This Drawing to be read in conjustion with
current soil test report and Mecano Floor Plan.
2. Concrete F'c = 20 MPa
3. Drilled holes shall be cleared from any loose
rock / dirt pior to concrete pour.
Minimum
150
4. Refer to MBP Sub Floor Bracing Detail.
5. Designed in accordance with AS2870.2011
and AS3600:2018
450 Minimum Dia
Mr Vic Bacud, Jnr
MIEAust CPEng RPEQ 3647 5 Pronger Parade Standard House Truss Details DATE : 26/09/2022
Mecano
NPER-3 Gympie Industrial Estate
Po Box 758
Typical Pad Footing DES SHEET 1 OF 1
Registered on the NPER-3 in the Category of SY
Civil and Structural Gympie Qld 4570 DWG. NO.
National Professional Engineers Register Section Three Sheds Pty Ltd DRWN SY
Ph (07) 5482 5614
COPYRIGHT: Email - [email protected] MBP-PF 1
CHK VB REV.