Geotechnical Report
The poorly compacted surficial fill encountered in the investigation may extend across the site boundaries. We therefore advise that sudden stop/start movements of any tracked equipment should be avoided in order to reduce transmission of ground vibrations to any adjacent buildings and structures within or neighbouring the site that are expected to be founded in the sands. 6.3.3 Seepage Groundwater seepage was not encountered in the GeoCon2012 investigation and the DCP testing completed by JKG did not indicate any traces of seepage within the 3.9m investigation depth. Elevated water levels are expected for the wetland area to the north-east although the wetland area is lower than the site. Some ephemeral seepage inflows may be encountered in the excavations, particularly after periods of heavy or prolonged rainfall. In general, we expect that inflows, if any, to be of very small volume and managed by infiltration into the sandy subgrade. Inspection and monitoring of groundwater seepage during excavations is recommended, so that any unexpected conditions, which may be revealed, can be incorporated into the drainage design. 6.4 Temporary Batter Slopes Temporary batter slopes through the sandy soil profile no steeper than 1 Vertical (V) in 1.5 Horizontal (H) are considered to be appropriate, though some surficial instability could still occur. These temporary batters will be achievable within the site geometry. Some instability of temporary sand batters may occur at, or below, the level of any groundwater seepage should it occur, especially after rain periods, and sand bagging may be required to stabilise the lower portion of these batters. Stockpiles of construction materials, excavated materials etc must be kept well clear of the crests to avoid surcharging the temporary batters, at a horizontal distance away from the cut batter slope crest equal to at least twice the height of the cut batter. 6.5 Footing Design The “uncontrolled” poorly compacted fill and very loose natural sands are not considered to be suitable foundation materials due to their low bearing capacity, potential for high elastic settlements and their susceptibility to additional settlements due to vibrations and infiltration of surface water run-off. Based on our assessment of the GeoCon2012 investigation results and our additional DCP test results, the natural sands of loose (or denser) relative density are considered to be a suitable foundation material. The loose (or denser) sands are expected to be encountered from depths of between about 1.4m and 1.8m below existing surface levels. 36409UR 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.