Council archive · source document
App E - Noosa Code Address · MCU25/0118
Performance outcomes Acceptable outcomes Solution Applicants Response
buildings; Management and
(e) avoid large areas of continuous wall Conservation Zone where
planes by varying the building setbacks the minimum setback is
and using appropriate techniques to 5m; or
provide visual relief; and
(f) help protect the natural character and b) for sites outside of the urban
boundaries at least:
visual amenity of the Noosa River system
and other watercourses where relevant. (i) for uses involving towers or
tanks, a distance at least
equal to the height of the
structure;
(ii) otherwise 10 metres from any
boundary.
AND
c) a distance greater the
riparian buffer area shown on
Biodiversity, Waterways and
Wetlands Overlay maps.
d) 100 metres from the level of
Highest Astronomical Tide (HAT)
in tidal areas (and to incorporate
natural vegetation and other
buffer elements)
e) 50 metres from freshwater
habitats (and to incorporate
natural vegetation and other
buffer elements)
AO19.2 Childcare centres
All buildings, structures and outdoor play
areas are set back at least 3 metres from all
site boundaries adjoining a residential
activity or land included in a residential
zone.
Noosa Plan 2020 – Amendment 1 – September 2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.