Council archive · source document
08/0831 - Response to Information Request [As Published] · 142008.831
10mm STIFFENER
12mm T-END PLATE
6 CFW TO PF3
6 CFW TO UB16
6 CFW TO BASE PLATE
ff-- 12mm STIFFENER
6 CFW TO PF3 16mm BASE PLATE
-1 2 M20 PF3 TO UB16 6 CFW TO PF3
2 M20 RODS 2 M20 RODS
CAST IN 1000 CAST IN 1000
50 z 50 x 6 MS WASHER 10mm END PLATE
6 CFW TO CH41 I I I '-10mm STIFFENER CLEATS
J
CFW TO BOTTOM OF EACH ROO
LJL-i 10mm CLEAT
6 CFW TO END PLATE
6 CFW TO UB10
2 M20 TO CH41
ROOF SECTION ALONG GRID 0 110 at Al TYPICAL CROSS BRACE & TIE FIXING DETAIL 116 at Al
CF zOzCMSWASHER
CFW TO EACH ROD
12mm STIFFENER
6 CFW TO UB16
SECTION R.O1 110 at Al
SECTION 110 at Al
UB28
12mm T CLEAT 12mm STIFFENER/CLEAT
6 CFW TO SH33 6 CFW TO FASCIA PFS
2 M20 TO PF5 2 M20 TO RAKING PF5
0mm STIFFENER 12mm T CLEAT COPE RAKING TO SUIT
6 CFW TO PFS 6 CFW TO 5H33
12mm T-END PLATE 2 M20 TO PF5
6 CFW TO PF5
12mm STIFFENER
6 CFW TO PF3
2 M20 PF3 TO PFS
ROOF SECTION ALONG GRID 10 110 at Al
FOR CONSTRUCTION
SURShRRI CoasR TITLE PROJECT PROPOSED DATE JANUARY 08
RX5 WIXG IS COPYRIGHT AND THE PROPERTY DE IARTOWGRFGG YDM PTY Lm
IT MUST NOT BE RETAINED COPIED OR USED WITHOUT THE AUTHORITY OF
BARLOWGRECU VON PTY LTD
XS
R
INi i AND ITS CONTENTS ARE ELECTRONICALLY GENERATED ARE
BARLOWGREGG L.VW 1 ST BroDans 0.ad
PD Bar IDO Maal0PIR0P DLD 1557
T .61 7 5464 0400
F .61 7 5416 1536
OOF FRAMING DETAILS
SHEET 2
FFICE DEVELOPMENT at
DRAWN
JBC
MSR
CONFIDENT L AND MAY ONLY BE USED FOR THE PURPOSE FOR WHEN THEY WERE
INTENDED BARLAWBREGO VON PTY LTD WILL NOT ACCEPT RESPONSIBILITY FOR ANY
EBNIANy.Rglo6RgroUP NN Pa
247 DAVID LOW WAY
TENDED N:ES ARISING FROM THE USE OF THE DRAWING FOR OTHER THAN ITS
COUSEQUE Fraser Coast CHECKED NDW
INTENDED
TENDED PURPOSE OR WHERE THE DRAWING HAS BEEN ALTERED AMENDED OR
CHANGED EITHER MANUALLY OR ELECTRONICALLY BY ANY THIRD PARTY Consulting Engineers T 61 77 4128 3055 PEREGIAN BEACH for
F 61 7 4124 1683 ASSOCIATED CONSULTANTS PROJECT SHEET NUMBER REVISION
A
15 SUED FOR CONSTRUCTION - LEADERS ADDED
ISSUED FOR TENDER
15072018
12032018
MSR
ACP HLE 15 AN UNCO D LED O
UNLESS THE CHECKED SECTIONS
ARE ISSUED FOR INFORMATION PURPOSES ONLY
NS ARE SIGNED OR COMPLETE
PLETED FIGURED
ACN 77 114 957 363 C oral C oas t ORE ARCHITECTURE MORGAN & BEIERS ATF
No AMENDMENT I DATE I BY No AMENDMENT DATE BY
TAKE PRECEDENCE OVER SCALED DO NOT SCALE REDUCED SIZE DRAWINGS
DRAWINGSS VERIFY
DIMENSIONS PRIOR TO COMMENCING ANY WORKS OR FABRICATION F IN DOUBT - ASK
www barlowgreggvdm com au T
F
Al 7 4152 6655
61 7 4157 6633 Ph 107) 5444 4511 Fox (07) 5444 4969 MULRANY PROPERTY TRUST 2 BM003087 - R-04-B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0831 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.