REIF. CONC. COLUMN NOTES
WALL REINFORCEMENT SCHEDULE 1 CONCRETE TO BE N40
WALL W1 - LOAD BEARING PRECAST PANEL 2 PROVIDE STARTERS TO MATCH VERT REINF
1 CONCRETE GRADE TO BE N40 LAP AS SPECIFIED WITH 400 COG TO ENDS
2 REFER Dwg SM003087-0.02 FOR CONSTRUCTION DETAILS (TYPICAL U NO) N12 DOWEL BARS 6001g
MESH - 250 N12 - 300 0 300crs EPOXY GROUT
WALL W2 - LOAD BEARING 210 SERIES BLOCKWORK
N16 - 400 N20 - 500 N12 DOWEL BARS 6001g TO WALL 100 EMBED c.
1 REINFORCE VERTICALLY WITH N16 AT ALL CORNERS ADJACENT TO OPENINGS AND
N24 - 600 N28 - 800 0 300crs EPOXY GROUT
VCJ S AND GENERALLY AT 400 MAXIMUM CENTRES
N32 - 1000 N36 - 1200 R6 LIGS TO WALL 100 EMBED
2 REINFORCE HORIZONTALLY WITH N12 ABOVE AND BELOW ALL OPENINGS AND 2 RIO LIGS 0 300
GENERALLY AT 400 MAXIMUM CENTRES ILAP 400 AS REQUIRED) 0 300 CTRS
3 WHERE A BAR LAPS WITH ONE OF GREATER
3 PROVIDE N16 STARTER BARS TO MATCH VERTICAL REINFORCEMENT 600 LAP
DIAMETER LAP LENGTH SHALL BE AS FOR
(U N 0 ) a 600 COG
S SPANS UP TO 3000mm PROVIDE SINGLE COURSE LINTEL OVER OPENINGS REINFORCE
THE LARGER BAR COLUMN C1 COLUMN C2
4 COVER TO MAIN REINF TO BE SOmm U N 0
HORIZONTALLY WITH 1 N16 CENTRALLY PLACED TOP & BTM
5 LIGS/HELICES SHALL BE LOCATED AT NOT
6 CONCRETE FILL ALL CORES 120MPa 230mm SLUMP 3mm MAXIMUM AGGREGATE SIZE) MAIN REINFORCEMENT
MORE THAN SOmm FROM THE BASE AND TOP
WALL W3 - LOAD BEARING PRECAST PANEL
1 150mm THICK PRECAST RC PANEL
OF COLUMNS (HELICES SHALL HAVE ONE AND
A HALF EXTRA TURNS AT THESE LOCATIONS)
COLUMN DETAILS 120 at Al BLOCK WALL
AS DETAILED
2 REINFORCE WITH SL82 MESH PLACED CENTRALLY & ADDITIONAL N16 BARS 0 200
Crs VERTICAL THROAT THICKNESS
3 REFER Dwg BM003087-D-03 FOR CONSTRUCTION DETAILS
WALL W6 - LOAD BEARING 200 SERIES BLOCKWORK
I REINFORCE VERTICALLY WITH N12 AT ALL CORNERS ADJACENT TO OPENINGS AND
VCJ S AND GENERALLY AT 400 MAXIMUM CENTRES STAIR TO LANDING DETAILS - BLOCK WALL
2 REINFORCE HORIZONTALLY WITH N12 ABOVE AND BELOW ALL WINDOW OPENINGS
AND GENERALLY AT 400 MAXIMUM CENTRES (LAP 400 AS REQUIRED) _UNDERSIDE SLAB
3 PROVIDE N12 STARTER BARS TO MATCH VERTICAL REINFORCEMENT 600 LAP BEAM OR DROP PANEL
(U N 01 a 600 COG
WALL WS - NON-LOAD BEARING 200 SERIES BLOCKWORK w
1 CONSTRUCT SIMILAR WALL TYPE W2 N12 DOWEL BARS 60018
2 a
PROVIDE 10mm COMPRESSIBLE FILLER TO TOP OF WALL AS REQUIRED 0 300crs EPOXY GROUT
_IL/^rJ L N12 DOWEL BARS 6001g TO WALL 125 EMBED 1
VC)
VERTICAL CONTROL JOINT AS DETAILED THIS DRAWING 0 300crs EPOXY GROUT
TOP OF COLUMN DETAIL TO WALL 125 EMBED
WITL
BLOCKWORK SHALL BE ADEQUATELY SUPPORTED AND BRACED OUR IG ERECTION TO AT FLOOR SLAB
RESIST ALL APPLIED WIND AND CONSTRUCTION LOADS
MAIN REINFORCEMENT
PRECAST PANEL
WALL AS DETAILED
u
a
a STAIR TO LANDING DETAILS - CAST INSITU WALL
STAIR TO LANDING DETAILS - PRECAST WALL SIMILAR
COMPRESSIBLE JOINT LOCATE TIE
FILLER WITH APPROVED AT CRANK
FLEXIBLE SEALANT 2 TIES AT 75
UNDERSIDE SLAB UNDERSIDE SLAB
BEAM OR DROP PANEL BEAM OR DROP PANEL
R16 GALV DOWEL BAR BLOCKWORK REINF AS DETAILED
600 LEGS CAP GREASE (DISCONTINUOUS AT JOINT) N
START (110)
& TAPE ONE END ONLY CRANK AT r
I-
DISTRIBUTION
PROVIDE DOWELS TO MATCHI JJ \r na
THIS POINT SUSPENDED SLAB REINFORCEMENT
HORIZ REINF LOCATIONS - VCJ DETAIL REINF AS DETAILED
COLUMN SPLICE DETAIL COLUMN SPLICE DETAIL AT FLOOR MAIN REINFORCEMENT
MAIN REINFORCEMENT
AT FLOOR SLAB SLAB - COLUMN SIZE CHANGE DISTRIBUTION
REINFORCEMENT 1000
STAIR TO SUSPENDED SLAB DETAILS
N12 CORNER BARS TO N12 INTERSECTION BARS
MATCH HORIZ REINF TO MATCH HORIZ REINF
LOCATIONS 400 LEGS LOCATIONS 400 LEGS STAIR NOTES
BLOCKWORK REINF BLOCKWORK REINF 1 REINFORCEMENT AS DETAILED
AS DETAILED AS DETAILED 2 PROVIDE 300 MIN LAPS CRANK ENDS OF REINF 200 AS
REQUIRED (UNLESS NOTED OTHERWISE)
CORNER DETAIL CORNER DETAIL 3 20mm COVER INTERNAL 45mm COVER EXTERNAL
4 CONCRETE GRADE TO BE N32 N12 0 300 EPOXY GROUT
200 INTO SLAB 400 LAP
5 REFER TO ARCH DWG S FOR ALL STAIR NUMBERS LOCATIONS
COMPRESSIBLE JOINT WITH STAIR REINF
FILLER WITH APPROVED SETOUT DIMENSIONS RISER COUNTS ETC
LOCATE TIE
FLEXIBLE SEALANT AT CRANK 6. CONFIRM ALL STAIR DIMENSIONS AND HEAD HEIGHT CLEARANCES
2 TIES AT 75 ON SITE PRIOR TO I[ONSTRUCTOL
R16 GALV DOWEL BAR 600
J UNDERSIDE SLAB
BEAM OR DROP PANEL
UNDERSIDE SLAB
1 BEAM OR DROP PANEL
7 LANDING THICKNESS 180mm Min UNLESS NOTED OTHERWISE
LEGS CAP, GREASE & TAPE ONE 2 TIES TO SUIT I LLOCATE STARTERS ON BOTTOM LOCATE STARTERS ON BOTTOM
END ONLY PROVIDE DOWELS TO STARTER BARS J REINF OF SLAB/FOOTING Mn REINF OF SLAB/FOOTING
STAIR REINFORCEMENT SCHEDULE
MATCH HORIZ REINF LOCATIONS START 11101 THROAT MIN MAIN DISTRIBUTION
CRANK AT a` THICKNESS REINFORCEMENT REINFORCEMENT
BLOCKWORK REINF AS DETAILED I
THIS POINT ALL STAIRS 170mm N12 0 300crs N12 0 300crs
(DISCONTINUOUS AT JOINT) COLUMN SPLICE DETAIL COLUMN SPLICE DETAIL AT FLOOR SLAB TO STAIR DETAIL
AT FOOTING OR SLAB SLAB - COLUMN SIZE CHANGE
VCJ AT CORNER DETAIL TYPICAL STAIR DETAILS 120 at Al
TYPICAL BLOCKWORK DETAILS 120 at Al TYPICAL COLUMN DETAILS 120 at Al FOR CONSTRUCTION
Sunshine Coast TITLE PROJECT
PROPOSED DATE JANUARY 08 SCALE AS SHOWN SEE Al
BARLOW
MG IS COPYRIGH AND THE PROPERTY .1 ARLowGREGG 014 PTY LTD
IT MUST MDT BE RETAINED
ALDMGRES
Pry ED D DEFIED DR USED WITHOUT THE AUTHORITY ON
AEGG VDH Pry LTD
tlING AND ITS CONTENTS ARE ELECTRONICALLY GENERATED ARE
BARLOWGREGG L...I I NI krzbAne Rnd
PO Bee 101 MewaWebe OLD LSS7
7 .111754441141111
F .61 7 5444 0536
WALL. COLUMN AND STAIR
SCHEDULES AND DETAILS
OFFICE DEVELOPMENT at
DRAWN
JBC
MSR
P VED
COFDENTIAL AND MAY ONLY BE USED FDA THE PURPOSE FOR WINCH THEY WERE
INTENDED BARLDWBREGG VON PTY LTD WILL LOT ACCEPT RESPONSIBILITY FOR ANY
EIaNFNyeg00rtlUyoup Ann (A
247 DAVID LOW WAY
CONSEQUENCES AR15NG FROM THE USE OF THE DRAWING FOR OTHER THAN ITS Fraser Coast CHECKED NOW ;PEG 3850
ISSUED FOR CONSTRICTION D111.011 MSR
INTENDED PURPOSE DR WHERE TIE DRAWING HAS BEEN ALTERED AMENDED DR
I(HAANNDED EITHER MANUALLY OR ELECTRONCALLY BY ANY THIRD PARTY Consulting Engineers T .611 4178 3955 PEREGIAN BEACH for
COLUMN WIDTH AMENDED 121.1008 MSR (H F .617 4124 1663 ASSOCIATED CONSULTANTS PROJECT SHEET NUMBER REVISION
A ISSUED FOR TENDER N142011 ACP 1X16 IS AN UNCONTROLLED DOCUMENT ISSUED FOR INFORMATION PURPOSES ONLY
UNLESS THE CHECKED SECTIONS ARE SIGNED DR COMPLETED. FIGURED DIMENSIONS
ACN 77 114 957 363 Coral Coast CORE ARCHITECTURE MORGAN & BEIERS ATF
No AMENDMENT DATE BY No AMENDMENT DATE BY
TAKE PRECEDENCE OVER SCALED DD NOT SCALE REDUCED SIZE DRAWINGS VERIFY
OPENSIONS PRIOR TO COMMENCING ANY WORKS DR FABRICATION F N DOUBT ASK
www badmvgreggvdm com au 7
F
.611 4152 66SS
.611 4S1 6633 Ph 101) 5444 4511 Fox 1071 5444 4969 MULRANY PROPERTY TRUST 2 BM003087 - 0-01-C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0831 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.