2783 Colour 110713 · MCU13/0098

of 4

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

 

 

 

STREET ADDRESS:

42 HOFFMAN DRIVE
NOOSAVILLE

REAL PROPERTY DESCRIPTION:

LOT 3 CANCELLING PART

CLIENT NAME:

MARKRIS

FOODS

Dive &

 

 

 

INTEGRATED WATER CYCLE MANAGEMENT NOTES:

 

 

LOT 2 SP

222982

 

 

Bartlett St

 

 

 

LOCALITY MAP

 

 

refer: "deemed to comply solutions — stormwater quality management
south east queensland’ version 1.0, may 2010 by "healthy waterways’

STORMWATER QUANTITY:
STORMWATER QUALITY:
FLOOD MANAGEMENT:
DEMAND REDUCTION:

ON SITE RETENTION TANK
DEEMED TO COMPLY SOLUTION Cl1

 

REFER MINIMUM FLOOR LEVELS
ROOF WATER HARVESTING AND
ASTAR WELS RATED FIXTURES

 

 

 

 

ADJACENT INDUSTRIAL ESTATE

NOTE:

DEPENDING ON GROUND CONDITIONS AND IF
REACTIVE SOIL IS FOUND ALL PENETRATIONS,
VERTICAL AND HORIZONTAL SHALL BE
PROVIDED WITH SWIVEL JOINTS AND
EXPANSION JOINTS. ALL SUBSURFACE DRAINS
REQUIRE EXPANSION JOINTS AT 10m SPACING.

 

INTEGRATED WATER CYCKLE

DRAWING SCHEDULE

 

 

MANAGEMENT PLAN

 

 

 

 

 

 

 

 

 

 

 

 

Site 3266 m?
Roof 1800__m?
Driveway 944 =m?
Landscape 522 m?
New impervious 2744 m?

2783-1 COVER SHEET

2783-2 STORMWATER DRAINAGE AND QUANTITY
2783-3 STORMWATER QUALITY DETAILS
2783-4 STORMWATER QUALITY MAINTENANCE

 

 

 

CATCHMENT AREAS

 

 

 

 

 

 

 

 

 

 

 

  

~~~ LAWFUL POINT OF

DISCHARGE

FOR DETAILS REFER TO
DRAWINGS PROVIDED BY
MORGAN CONSULTING

ENGINEERS.

 

 

  

PROPOSED NEW WAREHOUSE BUILDING

LOT 3

 

 

 

 

 

 

 

  
 

 

 

 

 

 

 

 

 

 

 

INTERNAL ACCESS ROAD (ROW)

 

 

 

 

 

 

 

 

 

 

 

SSB Se

 

 

 

 

 

 

] SITE ACCESS

  

 

 

fe ACCESS

 

 

 

 

 

 

 

 

Bn

 

Bth

 

 

 

FH
ME

a

 

Basin

Bath

Fire Hose Reel

Water Meter

 

 

 

 

 

 

Shr Shower

HWS Hot water system

cs Cleaners Sk

 

 

-AFTER EACH MAJOR RAINFALL EVENT
5.5. TO INSPECT AND CLEAN TANKS MINIMUM ONCE YEARLY.

5.6. TO INSTALL AND MAINTAIN PUMP AND FIXTURES FOR REUSE/WATERING/IRRIGATION AS TO MANUFACTURES SPECIFICATION 8.

7. FIRE AUTHORITY BOOSTER CONNECTIONS SHALL BE INSTALLED WITHIN 8M OF A ROAD, HARDSTAND OR THE LIKE TO WHICH THE FIRE

AUTHORITY PUMP APPLIANCE HAS ACCESS.

MATERIALS: <@100

CLASS 16 POLY / TYPE B COPPER IN GROUND.

TYPE B COPPER ABOVE GROUND.
>/= @100 CLASS 18 BLUE BRUTE IN GROUND.
FIRELITE ILG / TYPE B COPPER RISER/S.
9. DONOT USE GALVANISED FOR UNDERGROUND PIPE WORK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COVER SHEET

 

 

SCALE: NTS R EN ECE S T R EE E T
SITE PLAN & EXISITNG SERVICES DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
LEGEND GENERAL NOTES WATER SUPPLY Amd Description Bote
Rain Water 3 Diomeler 1. DONOT SCALE FROM THESE DRAWINGS. 1. PIPEWORK SHALL BE IN ACCORDANCE WITH AS4020, FOR EXAMPLE: ABS (ACRYLONITRITE STYTRENE), PP (POLY PROPYLENE), PE
Existing Woter ©.0.8.  Cleanout to surface 2. DO NOT RELY ON THESE DRAWINGS FOR ALIGNMENT AND LEVELS OF EXISTING INFRASTRUCTURE. (POLYETHYLENE) OR COPPER U.N.O.
s Existing Sewer CJ Capped junction 3. ITIS THE OBLIGATION OF THE CONTRACTOR AND/OR PLUMBING CONTRACTOR TO SURVEY ALL EXISTING SERVICES PRIOR TO 2. WATER SUPPLY PIPEWORK SHALL BE 20 U.N.O. EXCEPTION: ONE FITTING ONLY MAY BE @15. MAX. LENGTH 3000 MM. HOT WATER PIPEWORK|
Existing Storm water cv Conrol valve CONSTRUCTION. SHALL BE LAGGED. HOT WATER RECIRCULATING LINES TO BE INSULATED WITH 20MM "ARMAFLEX" OR SIMILAR.
HD Existing House drain cs Cleaners sink 4. THE PLUMBING CONTRACTOR IS OBLIGED TO OBTAIN REAL SIZE PRINT OUTS (A1 U.N.O.) FOR THE PREPERATION OF TENDER. ANY 3. PROVIDE TEMPERING VALVES ON HOT WATER TO PERSONAL HYGIENE FIXTURES.
Sanitary Drainage one Bold Water sanel CLAIMS REFERED TO AS "DRAWING COPIES" NOT READABLE SHALL BE REFUSED. 4. UNDERGROUND COPPER PIPEWORK SHALL BE "KEMLAGGED" OR OTHERWISE PROTECTED. UNDERGROUND PIPEWORK NOT UNDER
—sw—— Grey Water DOV Double check valve 5. ALL KITCHEN, LAUNDRY & BATHROOM FITTINGS AND TOILETS SHALL COMPLY WITH THE MINIMUM WELS WATER RATING LEVEL 4 CONCRETE SLAB MAY BE POLYPIPE CLASS PN20. ONE SIZE LARGER THAN SHOWN.
aaa vent fipe Een Eccentric Enlarger STAR (FORMER AAAA WATER CONSERVATION RATING AS PER AS/NZ6400). 5. EXPOSED PIPEWORK IN AMENITIES AREAS, SHALL BE CHROME PLATED.
oo Re wet Elev Dge Evevated Drainage 6. PROVIDE FLOW RESTRICTOR VALVES TO TAPS AND SHOWER ROSES WHERE REQUIRED. 6. SUBMETERS SHALL COMPLY WITH APPROVED DEVICES. REFER LOCAL AUTHORITY REGULATIONS. SUBMETERS SHALL BE LOCATED IN
Storm Water Drainage Fe False. ceiling 7. THE FLOW SHALL NOT EXCEED A MAXIMUM OF 9L/MIN. COMMON AREAS ONLY.
ooo _ Fire FH Fire Hydrant 8. WATER SUPPLY AND SANITARY DRAINAGE HAS BEEN DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE Q'LD
Agi Drain FHR Fire hose reel STANDARD SEWERAGE LAW, Q'LD STANDARD WATER SUPPLY LAW, THE NATIONAL PLUMBING, DRAINAGE CODE AS 3500, THE Tous ree Date
FFL Finished floor level Q'LAND DEVELOPMENT CODE QDC, THE FIRE HYDRANT CODE AS2419, ALL RELEVANT AUSTRALIAN STANDARDS, AND THE BACKFLOW PREVENTION
@)— Rain Water Ri fu Fixture units or t REQUIREMENTS OF THE LOCAL AUTHORITY. 1, PROVIDE HOSE CONNECTION VACUUM BREAKERS TO ALL HOSE COCKS PROVIDE RPZD TO ANY IRRIGATION CONNECTIONS, For Development Approval| X | 1-07-15
ee ain Water Riser GP Gully pt 9, THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL AND/OR HAZARD ZONES. For Building Approval
és) ° Cold Water Riser GMH Gully Man Hole DRAWINGS, OTHER CONSULTANTS DRAWINGS, SPECIFICATIONS AND OTHER WRITTEN INSTRUCTIONS THAT MAY BE ISSUED 2, PROVIDE APPROVED BACK FLOW PREVENTION TO FIRE SERVICES, HYDRANT SUPPLY (TESTABLE SINGLE CHECK VALVE U.N.O.), For Tender
@)— Down Pipe gv Gate valve DURING THE COURSE OF THE CONTRACT. ANY DISCREPANCIES SHALL BE REFERRED TO THE SUPERVISING OFFICER FOR ALL FIRE HOSE REELS WHICH MAY BE USED FOR OTHER THAN FIRE FIGHTING SHALL BE EQUIPPED WITH DOUBLE CHECK VALVES For Construction
=~ Stack HW Hot water tion branch DECISION BEFORE PROCEEDING WITH THE WORK. CONTRACTOR'S SHALL VERIFY ALL FIXTURE LOCATIONS, INVERT LEVELS, (DCV) U.N.O. As Constructed
@)- Vent Pipe HD House drain SURFACE LEVELS, AND COVER TO PIPES ARE CORRECT AND OBTAINABLE PRIOR TO COMMENCEMENT OF THE WORK. THE EXACT
@) 3 HL High level LOCATION OF EXISTING, AND PROPOSED SERVICES, SHALL BE VERIFIED WITH THE RELEVANT AUTHORITY, OR OTHER TRADES AS
Group Vent Ic Inspection Chamber APPLICABLE. FIRE STOP COLLARS TO BE USED ON ALL PLASTIC PIPEWORK PENETRATING FIRE RESISTANT CONSTRUCTION. COVERS & FRAMES
@)- cduct Vent IL invert. Level 1. COVERS SUBJECT TO VEHICULAR TRAFFIC TO BE 2535 CAST IRON, MEDIUM DUTY U.N.O.
3 io Inspection opening 2. COVERS IN GRASSED OR CONC. AREAS TO BE 2535 CAST IRON, CONCRETE INFILL LIGHT DUTY.
@ Fe lena Ri ios inspection Opening to Surface SANITARY DRAINAGE 3. COVERS IN PAVED AREAS TO BE 600 SQ. INFILL TO MATCH PAVING PATTERN. Hvd li we
o Hot Water Riser Kec Kerb & Channel 1. UNDERGROUND PIPEWORK SHALL BE @100 PVC DWV, AND UPVC WHERE EXPOSED, MIN GRADE 1:60 U.N.O. 4. COVERS IN TILED AREAS TO BE AS FOR PAVED AREAS WITH BRASS EDGING. y raullc =!
)Y. Fire Dropper NIRV Non esturn valve 2. SUSPENDED PIPEWORK SHALL BE PVC CLASS DWV. 5. CONCRETE INFILL COVERS TO BE STAMPED "SWD" OR "SEW" AS APPROPRIATE.
(8) Fire Riser PB Path box 3. TRADE WASTE PIPEWORK TO GREASE TRAP SUSPENDED SHALL BE "COESPRENE" OR HDPE.
PLV Pressure i 4. UNDERGROUND SHALL BE VITREOUS CLAY OR HDPE. i i
TACT: MIEAust RPEQ No 7023
Vv Veve PO Planter outlet 5. TRADE WASTE PIPEWORK TO OIL SEPARATOR SHALL BE HDPE, OR VITREOUS CLAY WITH'NITRILE” RUBBER RINGS. GRATINGS . . contact: Reinhold Koenning Mictus °
he Hose Cock Ree Real property Boundary 6. CLEANOUTS OR INSPECTION OPENINGS BROUGHT TO SURFACE IN PAVED OR CONCRETE AREAS, OR WITHIN BUILDINGS TO HAVE 1, GRATINGS FOR STORM WATER TO BE "FASTON, GATIC" OR APPROVED EQUAL DUTY TO MATCH MANUFACTURERS RECOMMENDATIONS Moffat Beach, QLD, 4551
—8 eal Property description _ FOR LOADING CONDITION. email: [email protected]
een Eccentric Enl WO luce Fressure, Zone device BRASS CAPS, SEALED AND SCREWED. 2. TRENCH GRATE TO BE TRANSVERSE BAR Pi: (07) 5491 4333 FX: (07) $491 4233
eccentric Enlarger RWO Rai ti thet . . : :
en Enlarger RWH Rain water head 3. FLOOR WASTE GRATES TO BE CHROME PLATED BRASS CLIENT
SD Sanitary Drainage
O / et Suton ‘evel FOENDERGROUND PIPEWORK SHALL BE @100 PVC CLASS SW MIN GRADE 1:100 U.N.O. MARKRIS FOODS
ORG Overflow Relief Gully sit Safe Tray 2. DOWNPIPES SHALL BE 100 PVC CLASS SW, U.N.O ON HYDRAULIC PLANS. FIRE SERVICE
Wat SwWD Storm water drain 3. RAINWATER OUTLETS (RWO) AND PLANTER OUTLETS (PO) SHALL BE "GATIC WADE" OR SIMILAR, WITH MEMBRANE CLAMPS WHERE 1, ALL HYDRANT PIPEWORK TO BE IN ACCORDANCE WITH AS2419-2005 CLAUSE 6.8. ARCHITECT :
[jo we Water, itd Trapped. Tundish REQUIRED. 2. ALL HYDRANT PIPEWORK TO BE IDENTIFIED IN ACCORDANCE WITH AS1345. SOUL SPACE
TG Test gate 4. GULLY PITS SHALL BE CONCRETE BODY IN TRAFFICABLE AREAS AND POLY IN NON TRAFFICABLE AREAS U.N.O 3. ALL HYDRANTS AND FIRE HOSE REELS SHALL HAVE A MINIMUM CLEARANCE (IN ALL DIRECTIONS) OF 100MM AROUND THE HANDWHEEL. <|
sk Sink td Tundish 5 POLLUTION CONTROL MANAGEMENT PLAN (PCMP); — 4. ALL HYDRANTS TO BE FITTED WITH THE VALVE OUTLET AT RIGHT ANGLES TO THE FACE OR WALL BEHIND IT. THE VAVLE OUTLET IS TO BE PROJECT: 42 HOFFMAN DRIVE
EO TG(t) Trench grate transverse bar . { i HORIZONTAL OR SLOPING AT A MAXIMUM OF 35 DEGREES BELOW HORIZONTAL.
iG suse tue TCI) Trench grate longitudinal bar 5.1. TO BE RESPONSIBILITY OF BODY CORPORATE. NOOSAVILLE
y TMV. Thermostatic. mhcng valve 52. TO LIST ALL IN FLOW FILTERING DEVICES LIKE LEAF EATERS AT DP'S AND OTHER FILTERS. 5. EXTERNAL FEED HYDRANTS SHALL BE POSITIONED WITHIN 20M OF A ROAD, HARDSTAND OR THE LIKE TO WHICH THE FIRE AUTHORITY PUMP INDUSTRIAL. DEVELOPMENT
Washin Vv Tempering valve 5.3. TO KEEP AND MAINTAIN A LOG OF CLEANING. APPLIANCE HAS ACCESS.
g
fol wm Machine u/g Underground 5.4. TO CLEAN DEVICES SUCH AS GUTTERS AND GULLY PITS: 6. EXTERNAL HYDRANTS SHALL BE POSITIONED NOT LESS THAN 10M FROM THE BUILDING UNLESS PROTECTED BY A CONSTRUCITON HAVING DRAWING TITLE:
u/s Under slab ; “AS TO MANUFACTURES SPECIFICATION A FIRE RESISTANCE LEVEL OF NOT LESS THAN 90/90/90 EXTENDING AT LEAST 2M EITHER SIDE OF THE HYDRANT OUTLET, AND WHICH EVER
8 FWG Floor Waste Gully un.o. Unless noted otherwise IS THE LESSER, 3M FROM THE GROUND LEVEL ADJACENT TO THE HYDRANT OR THE HEIGHT OF THE BUILDING
os WS Water supply -MINIMUM QUARTERLY, BUT MONTHLY IN RAINY SEASON , :
Et
i |

 

 

 

 

 

 

 

 

 

Design RH, Checked] Cu | Date 11—07—13 | Dwg. No. AMD.
\. SCALE: 1: 400 ON At UNo.| 1 of 4 2783-1 J
RPD:— LOT 3 / FMR LOT 2 SP 222982

 
Full text of the other 3 pages

Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a 60 ——-— NO RETENTION
oO
g 50: S WITH RETENTION
ty 40:

ADJACENT INDUSTRIAL ESTATE & 30. Zz ~
2 7 ~
S 70 _ oo =—
© 40 7 ~ ~
0 ! T I
2 4 6 8 10 12 14 16 18

rFOR DETAILS OF ROOF DRAINAGE REFER TO HYDRAULIC CONSULTANTS DRAWINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

     
   

 

 

 

 

 

 

 

 

 

 

 

 

  

  
 

 

 

 

 

 

 

 

 

TIME (MINS.)

STORMWATER HYDROGRAPH THROUGH TANK

PEAK FLOW MITIGATION THROUGH ON SITE RETENTION TANK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

| N - = = TOTAL PROPOSED TANK VOLUMES:
i COMBINED nN \ ee TANK FOR HARVESTING: 10,500 LITRE
ere} ere .
HARVESTING /RETENTION CE OOO eee Eee ee TANK FOR RETENTION: 12,000 LITRE
\ TANK, TYPE ABOVE Tee
\ GROUND. _| | | ~~ _
~~ TOTAL VOLUME | | ~ RUNOFF & DETENTION CALCULATIONS:
22,500LITRE | MAXIMUM EVENT: Q100
— DISCHARGE MINIMUM OF | | TIME OF CONCENTRATION: 5min
a 80% ROOF CATCHMENT | . INTENSITY: 326mm/hr
Tee AREA TO TANK. | y | SITE AREA: 3266sqm
IMPERVIOUS AREA: 2744sqm
| | PRE DEVELOPMENT PEAK RUNOFF: 260L/s
| & PEAK RUNOFF POST DEVELOPMENT: 290L/s (NO RETENTION)
\ | | |
ne A RETENTION VOLUME REQUIRED: 11,900 LITRE
~~ | ol |. —. 4}—-—-—--- RETENTION VOLUME PROVIDED: 12,000 LITRE
BIO RETENTION a
SYSTEM FOR\ | 9 | | ~ REDUCTION REQUIRED: 29.8L/s
ROOF CATCHMENT | |
MIN AREA 45sqm>\ | REDUCTION PROVIDED: 33.9L/s
~. |
9300 SHOWN BESIDE—— ||. | | FROM ROOF
BRS FOR CLARITY een
ONLY | a | =
IN
& TNT TTT TT VATTITTTIT NTT TTT TTT ITNT TTT TTT TTT NTT Nn TTT TTT TTT TTT TT TTT TTT MNT TT WTNKe- — HI-FLOW #300
~ BRS 3/1 rT? 3 Te
_ m
| %
wW bE
| gS 5
\ COMBINED ui
: heer HARVESTING / MITIGATION
\ wo
S Yt PROPOSED NEW WAREHOUSE BUILDING TANK 3
. 42000) TOTAL VOLUME:
\, A soa) O 22,500 LITRE
~ Le 50% HARVESTING YT )
~ 1L3.70 oO ~ |
ae & ~ Or eae ON LT 90 LO-FLOW SLOW
oe © 3b LEAK TO BIO
\ ~ iw RETENTION SYSTEM
S ee
7e5. N. 3
~~ GROUND
Se ~ NX NX N N NX N N N X« xX NO N\ X« ~~
-& FFL5.400 | ™-6  FFL5.400 [email protected] RAINWATER HARVESTING AND TO LAWFUL POINT OF DISCHARGE
MITIGATION TANK ASSEMBLEY
|_| SCALE: NTS
Ld ~
CARPARKING = ~
5 ~
S se
[email protected] FFL5.200 2 _
x ~~ DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
oN N [Amd Description Date
ee me DRIVEWAY ~
~~ 5/9.
10 oo CARPARKING
ie — 1L3.750:
1L3.510N Issue Notes Date
For Development Approval] X 11-07-13
Ne CARPARI For Building Approval
For Tender
_ LOT 3 PROPERTY CONNECTION
- _ 0375; 5.9m @ 1% For Construction
— USIL3.470 a.
so DSIL3.410 s Constructed
ae 225 BIO RETENTION BIO_ RETENTION
4175 1L3.510 L3.600 SYSTEM FOR SOUTH SYSTEM FOR
ee CARPARK NORTH CARPARK
oN CATCHMENT. CATCHMENT.
SV —=—EXISTING .
~ STORMWATER MIN AREA 11sqm MIN AREA 15sqm Hydraulic " 1
i MANHOLE 1/1:
se SL4.870 INTERNAL ACCESS ROAD (ROW)
se 1L3.555 y~ >|
aoe contact: Reinhold Koenning MiEAust RPEQ No 7023
= PO Box 181
~—— — SS — Moffat Beach, QLD, 4551
__ a 4 BE -4|75— a oo TT Te email: [email protected]
| = OS =< 4[5— ee ” PH: (07) 5491 4333 FX: (07) 5491 4233
_ ee ee oe oe CLIENT :
——— y MARKRIS FOODS
/ SITE ACCESS SITE ACCESS ARCHITECT -
/ \ SOUL SPACE
Z \ \ J
(Prosect: 42 HOFFMAN DRIVE »
NOOSAVILLE
R EF N €£ S T R & ET NBUBTRAE peveLorwenr
DRAWING TITLE:
STORMWATER
DRAINAGE
AND QUANTITY
Design RH, Checked] Ch | Date 11-07-13 | Dwg, No. AMD,
\ Scale: 1: 200 oN At uNo.| 2 of 4 2783-2 J
RPD:— LOT 3 / FMR LOT 2 SP 222982

 

 

 

 

 

 

 

 

 

 

 

Page 3

 

2000

22500

 

 

 

 

 

 

 

 

 

BIO RETENTION SYSTEM BRS 3/1

arp ica:

100 SLOTTED PVC WITH
CLEANOUT TO SURFACE
USING SCREW CAP.

 

 

ON SITE, ABOVE GROUND COMBINED
HARVESTING/RETENTION TANK WITH TOTAL
VOLUME OF 22,500 LITRES.

12,000 LITRE FOR RETENTION

10,500 LITRE FOR HARVESTING

300 HI-FLOW BYPASS BRS (NOT
SHOWN FOR CLARITY)

#90 LO-FLOW CHARGE ON TOP OF BRS

ON SITE, ABOVE GROUND COMBINED

HARVESTING/RETENTION TANK WITH TOTAL

VOLUME OF 22,500 LITRES.
12,000 LITRE FOR RETENTION
10,500 LITRE FOR HARVESTING
#300 HI-FLOW BYPASS BRS

#90 LO—FLOW CHARGE ON TOP OF BRS

ILTER MEDIUM SURFACE AREA WITH DENSE
PLANTING. FOR DETAILS OF SELECTED PLANTS SUCH
AS GRASSES, SHRUBS AND SELECTED TREES REFER
TO LANDSCAPE ARCHITECTS PLANS.

SL3.500

250 WIDE BATTER SURROUNDING BIO RETENTION SYSTEM.
ee: BATTER SHALL BE PROVIDED WITH ROCKS AND DENSE
oe PLANTING. FOR SELECTION OF PLANTS SUCH AS A

 

 

 

 

 

 

 

 

ae

 

BIO RETENTION SYSTEM BRS 3/1

 

 

 

SUBDRAINAGE LAYOUT

PLAN VIEW

MIXTURE OF GRASS, SHRUBS AND SELECTED TREES REFER
TO LANDSCAPE ARCHITECTS PLANS.

600sq HI-FLOW BYPASS AND
TRANSFER CHAMBER, CONCRETE WITH
ELEVATED GRATE AND WEIR AT
SL5.250

300 SYSTEM OUTFLOW

DIRECTED TO LAWFUL
POINT OF DISCHARGE

 

 

 

12,000 LITRE
RETENTION VOLUME

10,500 LITRE
HARVESTING VOLUME

 

300 HI-FLOW BYPASS
LOCATED UNDER BIO
RETENTION SYSTEM AND
CONNECTED TO SYSTEM
BYPASS CHAMBER AT
INVERT.

90 LOW-FLOW MITIGATION
DRAIN DISCHARGE TO TOP
OF BIO RETENTION SYSTEM
USING APPROVED FLAP
VALVE. CHARGE ON TOP OF
GRAVEL MATTRESS FOR
SCOUR PROTECTION.

 

 

600 FILTRATION ee

100 TRANSITION LAYER
200 DRAINAGE LAYER

250 EXTENDED DETENTION DEPTH

OOsq OVERFLOW AND HIGH
FLOW BYPASS CHAMBER,
CONCRETE WITH WEIR AT
SL5.250 AND HINGED,
ELEVATED GRATE.

5.300

 

 

 

 

5.000 y
y

4.400

 

 

 

 

 

 

 

 

 

4.300
NS 4.100

 

 

 

 

 

3 3.700

 

BIO RETENTION SYSTEM BRS 3/1
LONG SECTION

SECTION (Aa
SCALE 1: 201)

BIO RETENTION SYSTEM A NOTES
CATCHMENT: ROOF 1800m?

 

e FILTER MEDIUM AREA: 45m?

e¢ FORE BAY AREA: 1.5m?

e PROVIDE #100 SUBSOIL DRAINAGE WITH
CLEAN OUT POINTS AS INDICATED ON
PLAN.

250 EXTENDED DETENTION DEPTH

5.300

 

THE ENTIRE BRS TO BE ———
WRAPPED IN GEO TEXTILE

600 FILTRATION LAYER:

  
 

 

 

4.100
100 TRANSITION LAYER: _ Nes
3.700
200 DRAINAGE LAYER 0
#300 TO TRANSFER/BYPASS
CHAMBER
BIO RETENTION SYSTEM BRS 3/1
CROSS SECTION
SECTION /—B \
SCALE 1: 201)
NOTE:

IDENTICAL CONSTRUCTION PRINCIPLES
APPLY FOR BRS 3/2 AND BRS 3/3

         

#300 TO LAWFUL POINT OF
DISCHARGE

DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING

FOR ASSESSMENT, TENDERING AND CONSTRUCTION.

IS USED

 

[Amd Description

 

 

 

 

 

 

 

 

 

 

 

 

Issue Notes

 

For Development Approval] X

11-07-13

 

For Building Approval

 

For Tender

 

For Construction

 

As Constructed

 

 

 

 

E Hydraulic

 

 

PO Box 181
Moffat Beach, QLD, 4551
email: [email protected]

contact: Reinhold Koenning MiEAust RPEQ No 7023

PH: (07) 5491 4333 FX: (07) 5491 4233

 

 

 

NOOSAVILLE
INDUSTRIAL DEVELOPM

CLIENT
MARKRIS FOODS
ARCHITECT :
L SOUL SPACE J
(Prosect: 42 HOFFMAN DRIVE Y

ENT

 

DRAWING TITLE:

 

 

 

 

 

 

 

 

 

 

STORMWATER

QUALITY

DETAILS
Design| RK. Checked | Cu | Date 11—07—13 | Dwg. No. AMD.
\ SCALE: 1: 50 on At u.N.o.| 3 of 4 2783-3 J
RPD:— LOT 3 / FMR LOT 2 SP 222982

 

 

Page 4

 

 

RECOMMENDATIONS FOR ESTABLISHMENT & OPERATION:

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

  

 

 

 

 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHASE OF ESTABLISHMENT: SPECIFICATIONS
Shr Roof water
= DW
The first 2 Years after construction are crucial for the performance of the VBFS.
cto one Pero: : . TANK SPECIFICATION ‘em
Ensure the right plant selection (refer "Healthy Waterways" for plant selection) oo tLe __| |
HED) i j j Fi ( TANK SIZE: 10,000 LITRE wm Vv
During dry periods provide sufficient watering DESCRIPTION: PRECAST kno TEOEND
Perform regular weed removal ' r Tone |
fee : : | 1 SOLENOID SWITCHOVER DEVICE
Replace not established plants where required PUMP SPECIFICATION i! 2 RAIN HEAD IF APPLICABLE
OPERATIONAL PHASE: vawncete we f! A | 2 [SESE es mpcaron
. ; ; ; ; ; ; ; . ; MODEL ACTURER: The my | 5 |PRESSURE LIMITING VALVE, 500 kPA MAX.

e Perform routine inspections of the raingarden (VBFS) to identify any areas of obvious increased sediment deposition, scouring from | | No No § BERING VALVE MAX SOC
storm flows, rill erosion of the batters from lateral inflows and clogging SWITCHOVER DEVICE SPECIFICAITON Mt M | 8 | FILTRATION DEVICE

e Perform routine inspections of the inflow systems in particular the grated drain and clean the grated drain regular from debris and litter Heater NC | 9 | RAINWATER PUMP

oe : : : . >60°C NRV —— NO |NORMALLY OPEN
e Perform routine inspections of the surface of the raingarden and clean from litter and gross pollutants MANUFACTURER: TBC z : NC | NORMALLY CLOSED
: : : : MODEL: TBC &]| | Harvesting |
e Remove sediment build ups in the raingarden E|| | Zone Vo) BALL VALVE
: : : HWS ® $ GV | GATE VALVE

e — Repair any damage from vehicle traffic x 36 | NRV|NON-RETURN VALVE

e Provide regular irrigation/watering during extended dry periods RAINWATER FILTRATION SPECIFICATION - I v Vv Vv | DCV| DOUBLE CHECK VALVE

e Remove any invasive weeds at any time MANUFACTURER: TBC mark “RAIN WATER NRV GV [Sludge zone |

e Remove plants that have died and replace them , RPB Towns

e Perform regular pruning as to Landscape Architects schedule to encourage growth and healthy establishment of plants Syoton ee main

e Perform vegetation pest minotoring and control as to Landscape Architects schedule HOT WATER SYSTEM SPECIFICATION

MANUFACTURER: TBC
RECOMMENDATION: MODEL: TBC RAINWATER HARVESTING SCHEMATIC
THE RAINGARDEN IS PROPOSED TO BE A STORMWATER TREATMENT DEVICE AS OPPOSED TO A NORMAL GARDEN
BED. WE RECOMMEND TO SET UP A SIGN EXPLAINING THE PURPOSE OF THE RAINGARDEN.
WIDTH AS SPECIFIED IN PLAN VEGETATED BIO RETENTION SYSTEM LENGTH AS SPECIFIED IN PLAN WIDTH AS SPECIFIED IN PLAN NOTES: — 8 0 0 =
Use for mulching: LUCERN, WOODCHIP OR EQUIVALENT. 7. Use LUCERN OR EQUIVALENT for mulching
FILTER LAYER: 2. Do not use organic Soils or soil fractions
Clay 2-4% (<0.002mm) for filter layer. , , ; i
Silt 4-8% (0.002-0.05mm) 3. Provide a suitable irragation system required
Very Fine Sand —_5-10%(0.05-0.15mm) for the establishment of the plants and for rom car ar
Fine Sand 10-25% (0.15-0.25mm) use in extended dry periods. Irragation
Med./Coarse Sand 60-70% — (0.25-1.0mm) system shall be supplied from the -
Coarse Sand 7-10%(1.0-2.0mm) harvesting tanks. oO
4. Do not use any geotextile or related wo
TRANSITION LAYER: products between filter and transition or
Coarse Sand 100% 0.5-2 mm between transition and drainage layers.
DRARAGE LAYER oe ene hncarden | |
oO O Fine Gravel 100% 2-5 mm 6 Crovide flush out points for subsurface " oO A raingarden is a garden bed which
. * oO . :
Provide b drainage. wo uses native plants and free drainage to
© base grad 9
© at 0.5% (1:200) i A soils to treat the pollutants formed in
Connect subsoil .
drainage to stormwater to stormwater that runs off the driveway
Provide PVC perforated pipe with infrastructure as — Cc re e
diameter as specified in plan. specified in pian. and carpark. Raingardens help to
Minimum 2 off.
protect our waterways. 4
VEGETATED BIO FILTER STRIP SOIL SPECIFICATION
(NOT TO SCALE) Y lo
NOTES: —
1. Provide selected plants as to specification of
"Healthy Waterways” http://www.healthywaterways.org/
2. Provide "FOREBAY’ made of rocks and pebbles. For
scour protection. Refer detailed design for area.

WATER SENSITIVE URBAN DESIGN TECHNICAL DESIGN GUIDELINES FOR SOUTH EAST BIORETENTION FILTER & RAINGARDEN MAINTENANCE CHECKLIST

QUEENSLAND (Chapter 5, Item 5.6).

The maintenance of the bioretention basin elements involve:

. . . , . vp yg oo . BODY NAME: DATE:

e Routine inspection of the bioretention basin profile to identify any areas of obvious increased sediment CORPORATE DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
deposition, scouring from storm flows, rill erosion of the batters from lateral inflows, damage to the profile RESPONSIBILITY CENTRE FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
from vehicles and clogging of the bioretention basin (evident of "boggy" filter media surface). MANAGEMENT NAME: DATE: (Amd Description Date

e — Routine inspection of inflows systems, overflow pits and under-drains to identify and clean any areas of
scour, litter build up and blockages. OWNER NAME: DATE:

e Removal of sediment where it is smothering the bioretention basin vegetation. TRO NAME AND ES OF

e Where a sediment forebay is adopted, removal of accumulated sediment. INSPECTION OUARTER .

e Repairing any damage to the profile resulting from scour, rill erosions or vehicle damage by replacement of FREQUENCY 6—MONTHLY
appropriate fill (to match onsite soils) and revegetating. DROUGHT

e — Tilling of the bioretention basin surface, or removal of the surface layer, if there is evidence of clogging. AFTER EVENT

e — Regular watering/irrigation of vegetation until plants are established and actively growing. INSPECTION ITEMS Yes _|No ACTION REQUIRED

e Removal and management of invasive weeds (herbicides should not be used).

e Removal of plants that have died and replacement with plants of equivilant size and species as detailed in pveral appearance healthy? Issue Notes Date
the plant schedule. Grane Her on wanlase? For Development Approval] X 11-07-13

e Pruning to remove dead or diseased vegetation material and to stimulate growth. For Building Approval

e Vegetation pest monitoring and control. Sediment accumulation at inlet? For Tender

For Construction
Sediment accumulation on pebble surface?
Refer "Water by design" by HEALTHY WATERWAYS. As_Constructed
Sediment accumulation at pipe outlets?
Sediment accumulation in bypass chamber?
HARVESTING Erosion at forebay? .
&
RETENTION Erosion at overflow? Hyd raulic i
2 TANK Any other erosion?
son? SAS]
Damage of support structure? contact: Reinhold Koenning MigAust RPEQ No 7023
ROOF Any other traffic d 1? Morte Bees
ny other fratite Gamage present? Moffat Beach, QLD, 4551
Damage to grates and lids? email: [email protected]
PH: (07) 5491 4333 FX: (07) 5491 4233
Visual plant health ok? CLIENT :
Weeds apparent? Weeding required?
382m? BIO RETENTION SYSTEM BRS3/1 Watering required? MARKRIS FOODS
Irrigation functional?
Replanting required? ARCHITECT :
ee Mowing/slashing/pruning required? Ne SOUL SPACE J
DRIVEWAY Surface clogging visible? (PRovect: 42 HOFFMAN DRIVE Y
2 BIO RETENTION SYSTEM BRS. 3/2 Excess ponding evident? NOOSAVILLE
562m Flushing required? INDUSTRIAL DEVELOPMENT
ee Point of discharge inspected (pit/headwall/swale/creek)? DRAWING TITLE:
DRIVEWAY BIO RETENTION SYSTEM BRS 3/3 RECEIVING WATERWAYS OBSERVATIONS STORMWATER
QUALITY
MAINTENANCE
TREATMENT TRAIN SIGNATURE & DATE:
NOTE: A4 COPIES OF THE FORM CAN BE OBTAINED BY CONSTRUCTION HYDRAULIC | | |
Design| WeH.|Checked| ©} Date |11—O07—13 | Dwg. No. AMD,
(SCALE | N/A ON At un.o.| 4 of 4 2783-4 J

 

 

 

 

 

RPD:-— LOT 3 / FMR LOT 2 SP 222982

 

 

Used in these records

About this file

File size
1.6 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2783 COLOUR 110713.pdf · 1.6 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.