Driveway Location AO14.1 Only one driveway and Complies with AO14.1
PO14 Driveways and crossovers crossover is provided. One driveway and crossover is
are located so they do not impede proposed.
the safe and efficient use of the AO14.2 Where the premises has
road network. Not applicable
frontage to more than one formed
and sealed road and the roads have
differing orders in the Road
Hierarchy, the driveway and
crossover is provided on the
frontage with the lower order.
AO14.3 For corner lots, driveways Not applicable
and crossovers are located in The site is not a corner lot.
accordance with Council's standard
drawings.
Not applicable
AO14.4 If in the Rural zone or
The site is not in the Rural or
Rural Residential zone, the
Rural Residential zones.
driveway and crossover is located
to provide minimum safe sight
distances in accordance with
Austroads.
Editor's Note - An operational works
application is required for a second
driveway.
Bushfire Hazard Management AO15 Within a bushfire hazard Can comply with AO15
PO15 Where located in a Bushfire area where there is no reticulated
Hazard Area as shown on the water supply, the premises has:
Bushfire Hazard Overlay Map in 1. an accessible dam,
Schedule 2 and not in a water swimming pool or water tank
service area, an adequate, reliable, available for firefighting purposes
safely located and freely accessible with an onsite water volume of not
water supply is provided for fire less than 5,000 litres; and
fighting purposes, which is in 2. a water supply outlet pipe
addition to day to day water supply. 50 millimetres in diameter and
fitted with a standard fire brigade
fitting connected to the water
supply (other than where the water
supply is in a swimming pool or
dam).
Editor’s Note — Water supply
capacity for firefighting purposes is
in addition to water supply capacity
for household use.
Flood Hazards AO16.1 Where the development is Not applicable
PO16 Development is designed located in the Flood Hazard Area as The site is not mapped as
and sited to ensure risk to people shown on Flood Hazard Overlay containing flood hazard areas.
25
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.