2016-04-19 P&E Committee - Item 1, Attachment 2 - Air Quality Assessment Report
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
⚫ worst case CAPCOA “whoosh” emissions adopted to represent slightly higher volatility of
Australian fuels.
⚫ A factor of 1.20 has been applied to the emission rate to account for E10 fuel sold (20% of E10
fuel sold compared to other fuel types based on proposed tank volumes and a factor of 1.5 for
the E10 proportion only).
4.9 Modelling Results
Tables 4.2 and 4.3 presents the predicted maximum concentrations at the subject site. Figures 4.2
and 4.3 present the pollutant concentration contours for odour and benzene (cumulative) in the
modelled area.
Table 4.2: Predicted VOC Results – Maximum Predicted Concentrations at Modelled Sensitive
Receptors
Maximum Predicted
Concentrations at Modelled Air Quality Goal
Compound Averaging Time
Sensitive Receptors (g/m3) (g/m3)
Source Only Cumulative
Benzene 0.23 3.1 10 Annual
54 79.5 958 30 Minutes
Toluene 10.1 35.7 4,100 24 Hour
0.88 17.1 410 Annual
Ethylbenzene 3.4 3.4 8,000 1 Hour
4.1 47.9 1,200 24 Hour
Xylenes
0.35 27.2 950 Annual
Cyclohexane 2.8 2.8 19,000 1 Hour
n-Hexane 75 75.1 3,200 1 Hour
0.49 0.49 65 30 Minutes
Styrene
0.0089 0.0089 280 7 days
1 Hour, 99.5th
Odour 0.7 0.7 2.5 OU
Percentile
Page 23 of 30
Synergy Property Partners Pty Ltd- Air Quality Assessment - Proposed Service Station, 123 Eumundi-Noosa Road, Noosaville
/Network/Projects/4484/Reporting/4484 Report03.odt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.