Council archive · source document
KL15B13_Corsair 19A17_FC · OPW19/0021
Attached to the e-mail Operational Works Application OPW19-0021 3of3 Architectuals.msg.
REFLECTED CEILING
PLAN LEGEND
POWER, SOCKETS & OTHER NO. DESCRIPTION DATE
s HARD WIRED SMOKE
DETECTOR
WP DPP
WEATHERPROOF DPP
DPP @ 300mm ht
DPP @ 1050mm ht
DPP @ 1500mm ht
GPO for Rangehood
GPO for Dishwasher
TELEPHONE JACK
DATA POINT
AV / COAXEL/DATA/
AUSTAR WALL SOCKET
MSB
MAIN SWITCH BOARD S
MB
ELECTRICAL METER S
ROBE
ROBE
MSB
MECHANICAL VENT.
HWS
HOT WATER STORE S S
WP DPP BATH / LDY BED 3
CH2400 CH 2400
BATH / LDY
LIGHTS CH 2400
BED 3 PROJECT ADDRESS:
FAN WITH NO LIGHT CH 2400
3 Corsair Cres,
T5 21w recessed fluoro Sunrise Beach Qld
to overhead
cupboards AUSTRALIA 4567
WEATHER PROOF /
s
WALL WASHER LIGHT
HWS
MB
WEATHER PROOF
UP DOWN LIGHT
2 CAR GARAGE CLIENT:
CH 2400 A. Warner /
OYSTER LIGHT WITH Door K & C Hendrie
APPORVED GLOBE Motor C/- PO Box 1234
BED 2
MSB
PENDANT LIGHT CH 2400 Noosa Heads QLd 4567
P 2 CAR GARAGE
CH 2400 BED 2 ENTRY ENTRY
RECESSED DNLT. VOID VOID DESIGNER:
S CH 2400 Annette Warner Pty Ltd
1 x 1200/36W FLOURO.
Building Design Consultants
2 x 1200/36W FLOURO. PO Box 1234
Noosa Heads Qld 4567 Australia
TASTIC
FAN/LIGHT/HEATER ph: +61 7 5447 4893
VANITY FLURO
SWITCHES COURTYARD COURTYARD
DRAFTING:
SINGLE SWITCH PLATE WP DPP PORCH PORCH
SINGLE SWITCH PLATE
WITH FAN SPEED DIAL
PO BOX 687,
DOUBLE SWITCH PLATE NOOSA HEADS, QLD 4562
WITH FAN SPEED DIAL EMAIL: [email protected]
G QBCC: 1285397
TRIPLE SWITCH PLATE
WITH FAN SPEED DIAL JOB NO.
IT KL15B13
2 WAY SWITCH w/ light
3 WAY SWITCH
Proposed Ground Floor
1 1 : 100
DRAWING TITLE
GROUND FLOOR RCP
SOLAR HWS TUBES ON ROOF.
STORAGE TANK UNDER STAIRS
DRAWING NUMBER
A200
Scale as shown @ A3
NOTES
3. FIGURE DIMENSIONS ONLY ARE TO BE USED, WITH NO DIRECT SCALING FROM
Rev Date : Rev No :
1. GENERALLY THE BUILDER SHALL COMPLY WITH THE REQUIREMENTS 5. BUILDING METHODS ARE SUGGESTED ONLY. THE CONTRACTOR REMAINS
OF THE LOCAL AUTHORITIES AND ADHERE TO THE PROVISIONS OF THE THE DRAWINGS ALLOWED. RESPONSIBLE FOR ALL METHODS AND MATERIALS CONFORMING TO THE
APPROPRIATE CODES AND STANDARDS
CONSTRUCTION ISSUE 17/01/19 F
BUILDING CODE OF AUSTRALIA
4. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED
2. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE CHECKED 6. ALL SCHEDULES ARE PROVIDED TO ASSIST WITH ESTIMATION ONLY.
AND VERIFIED ON SITE BEFORE BUILDING WORK COMMENCES
ON SITE BEFORE WORK COMMENCES, ANY QUIERIES ARE TO BE DIRECTED IT IS THE RESPOSIBILITY OF THE BUILDER / CONTRACTOR
TO CONFIRM ALL QUANTITIES
FOR CONSTRUCTION Drawn by : Checked by :
TO THE DESIGN AUTHORITY - ANNETTE WARNER PTY LTD
AXK AW
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
KL15B13_Corsair 19A17_FC.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.