KL15B13_Corsair 19A17_FC · OPW19/0021
Attached to the e-mail Operational Works Application OPW19-0021 3of3 Architectuals.msg.
NO. DESCRIPTION DATE
REFLECTED CEILING
PLAN LEGEND
POWER, SOCKETS & OTHER
s HARD WIRED SMOKE
DETECTOR
WP DPP
WEATHERPROOF DPP
DPP @ 300mm ht
DPP @ 1050mm ht
DPP @ 1500mm ht
GPO for Rangehood
GPO for Dishwasher
TELEPHONE JACK
DATA POINT
AV / COAXEL/DATA/
AUSTAR WALL SOCKET
MSB
MAIN SWITCH BOARD
MB
ELECTRICAL METER
PDR PDR
R/H CH 2400 CH 2400 KITCHEN DECK
MECHANICAL VENT.
WP DPP C/T Raked Ceiling
HWS KITCHEN OVEN PROJECT ADDRESS:
HOT WATER STORE
Raked Ceiling
ENSUITE 3 Corsair Cres,
LIGHTS CH 2500
U/B ENSUITE Sunrise Beach Qld
O/H CH 2500
FAN WITH NO LIGHT
SHOWER AUSTRALIA 4567
T5 21w recessed fluoro Robe
to overhead Robe
cupboards
CLIENT:
WEATHER PROOF /
WALL WASHER LIGHT A. Warner /
K & C Hendrie
WEATHER PROOF C/- PO Box 1234
UP DOWN LIGHT
P LOUNGE MASTER BED Noosa Heads QLd 4567
OYSTER LIGHT WITH VOID DINING
DINING Raked Ceiling 2550
APPORVED GLOBE DESIGNER:
PENDANT LIGHT
MASTER BED LOUNGE Annette Warner Pty Ltd
CH 2550 VOID
P Raked Ceiling Building Design Consultants
RECESSED DNLT. PO Box 1234
s Noosa Heads Qld 4567 Australia
1 x 1200/36W FLOURO.
ph: +61 7 5447 4893
2 x 1200/36W FLOURO.
TASTIC
FAN/LIGHT/HEATER
DRAFTING:
VANITY FLURO
SWITCHES
PO BOX 687,
SINGLE SWITCH PLATE
NOOSA HEADS, QLD 4562
EMAIL: [email protected]
SINGLE SWITCH PLATE QBCC: 1285397
WITH FAN SPEED DIAL
DOUBLE SWITCH PLATE
JOB NO.
WITH FAN SPEED DIAL KL15B13
TRIPLE SWITCH PLATE
WITH FAN SPEED DIAL
2 WAY SWITCH DRAWING TITLE
Proposed First Floor
3 WAY SWITCH
1 1 : 100
FIRST FLOOR RCP
DRAWING NUMBER
A201
Scale as shown @ A3
NOTES
1. GENERALLY THE BUILDER SHALL COMPLY WITH THE REQUIREMENTS 3. FIGURE DIMENSIONS ONLY ARE TO BE USED, WITH NO DIRECT SCALING FROM 5. BUILDING METHODS ARE SUGGESTED ONLY. THE CONTRACTOR REMAINS Rev Date : Rev No :
OF THE LOCAL AUTHORITIES AND ADHERE TO THE PROVISIONS OF THE THE DRAWINGS ALLOWED. RESPONSIBLE FOR ALL METHODS AND MATERIALS CONFORMING TO THE
BUILDING CODE OF AUSTRALIA
4. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED
APPROPRIATE CODES AND STANDARDS CONSTRUCTION ISSUE 17/01/19 D
2. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE CHECKED 6. ALL SCHEDULES ARE PROVIDED TO ASSIST WITH ESTIMATION ONLY.
AND VERIFIED ON SITE BEFORE BUILDING WORK COMMENCES
ON SITE BEFORE WORK COMMENCES, ANY QUIERIES ARE TO BE DIRECTED IT IS THE RESPOSIBILITY OF THE BUILDER / CONTRACTOR
TO THE DESIGN AUTHORITY - ANNETTE WARNER PTY LTD
TO CONFIRM ALL QUANTITIES FOR CONSTRUCTION Drawn by : Checked by :
AXK AW
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
KL15B13_Corsair 19A17_FC.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.