KL15B13_Corsair 19A17_FC · OPW19/0021
Attached to the e-mail Operational Works Application OPW19-0021 3of3 Architectuals.msg.
NOTE: 2
ALL RL's TO EXISTING SLAB LEVEL, NOTE:
INTERTENANCY WALL DETAILS A300 OVERALL HEIGHT NOT TO EXCEED 8M
PLUS 200mm TOPPING SLAB TO
STRUCT. ENG. DETAILS ROOF PITCH
TOP OF ROOF 12.0°
745
450
RIDGE LINE ROOF PITCH
1115
1230
W11 12.0° NO. DESCRIPTION DATE
150
0550
ENTRY
STRUCTURE
LB
3900
3245
W08
3110
DINING KITCHEN
2550
2550
1212
BEYOND
7345
W13
DECK
DECK 2107
LB
SECOND FLR FFL
2700
2700
2400
LB 2 CAR GARAGE LB
GROUND FLOOR FFL
W01
2105
ALL FLOORS AND
STRUCTURE TO
SECTION AA
1 1 : 100
STRUCT. ENG. DETAILS
PROJECT ADDRESS:
3 Corsair Cres,
EQ EQ Sunrise Beach Qld
AUSTRALIA 4567
ROOF
INTERTENANCY WALL 1
EQ EQ
A300 ROOF
CLIENT:
TOP OF ROOF A. Warner /
K & C Hendrie
745
ROOF
RIDGE LINE C/- PO Box 1234
W11 Noosa Heads QLd 4567
0550
DESIGNER:
Annette Warner Pty Ltd
KITCHEN KITCHEN Building Design Consultants
Raked Ceiling Raked Ceiling PO Box 1234
3900
W07 Noosa Heads Qld 4567 Australia
1205 ENSUITE DECK W09 PDR PDR DECK ENSUITE ph: +61 7 5447 4893
BEYOND 1221 BEYOND BEYOND BEYOND
D18
6600
DRAFTING:
SECOND FLR FFL
W03
0515
PO BOX 687,
NOOSA HEADS, QLD 4562
2700
EMAIL: [email protected]
D04 2 CAR GARAGE D05 BED 3 BATH / LDY BATH / LDY BED 3 2 CAR GARAGE QBCC: 1285397
JOB NO.
GROUND FLOOR FFL KL15B13
UNIT 2 UNIT 1 DRAWING TITLE
PROPOSED SECTION
SECTION BB
2 1 : 100 DRAWING NUMBER
A300
Scale as shown @ A3
NOTES
1. GENERALLY THE BUILDER SHALL COMPLY WITH THE REQUIREMENTS 3. FIGURE DIMENSIONS ONLY ARE TO BE USED, WITH NO DIRECT SCALING FROM 5. BUILDING METHODS ARE SUGGESTED ONLY. THE CONTRACTOR REMAINS Rev Date : Rev No :
OF THE LOCAL AUTHORITIES AND ADHERE TO THE PROVISIONS OF THE THE DRAWINGS ALLOWED. RESPONSIBLE FOR ALL METHODS AND MATERIALS CONFORMING TO THE
BUILDING CODE OF AUSTRALIA APPROPRIATE CODES AND STANDARDS CONSTRUCTION ISSUE 17/01/19 I
4. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED
2. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE CHECKED 6. ALL SCHEDULES ARE PROVIDED TO ASSIST WITH ESTIMATION ONLY.
AND VERIFIED ON SITE BEFORE BUILDING WORK COMMENCES
IT IS THE RESPOSIBILITY OF THE BUILDER / CONTRACTOR
ON SITE BEFORE WORK COMMENCES, ANY QUIERIES ARE TO BE DIRECTED
TO THE DESIGN AUTHORITY - ANNETTE WARNER PTY LTD
TO CONFIRM ALL QUANTITIES FOR CONSTRUCTION Drawn by : Checked by :
AXK AW
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
KL15B13_Corsair 19A17_FC.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.