GENERAL SITE PLAN NOTES
EARTHWORKS TO BE IN ACCORDANCE
WITH LOCAL COUNCIL REGULATIONS
‘AND NATIONAL CONSTRUCTION CODE,
VOL 2, SECTION 3.1.1 EARTHWORKS.
STORMWATER DRAINAGE DESIGN &
COMMUNITY TITLE SUBDIVISION
Total Lot Size = 1,007m2
DISCHARGE TO AS 3500, SECTION 3.1.2
STORMWATER DRAINAGE, NCC VOL2
AND LOCAL COUNCIL REQUIREMENTS.
DRIVEWAY CROSSOVER DESIGN,
CONSTRUCTION AND FINISH TO LOCAL
COUNCIL REQUIREMENTS.
‘SERVICES LEGEND
UNDERGROUND ELECTRICAL
Alfresco to be
reduced in size in
accordance with the
site cover plan
Proposed Lot |= 513m)
Preposed-batd—O4m2
Shared fence easement (6m2 (0.3m x 20m))
Sewer Easement = 274m2
OVERHEAD ELECTRICAL
RAINWATER DRAINAGE
s STORMWATER
7— TELSTRA
—"— WATER
Stormwater Easement (~15m2)
Landscaping in accordance with Planning Scheme Policy 03
- 2.x street trees to Opal St
- Dense landscaping around perimeters and in front of Opal St fence
DEVELOPMENT DETAILS
Density = 2 x 3+ beds (6.6)
Site Gover =220+-220-=410-(44%)-
Plot Ratio = 137 + 144 = 281m2 (27%)
Parking = 4 spaces
Landscaping = 496m2 (49%)
* New driveways and crossovers in
accordance with RS-049 & RS-050
Existing Feiiee
Fn
Kitchen
I
OPAL STREET
\ ‘TOP Pi
Easements fot Services (inidcative)
- Sewer easement(1.5m either side of existing pipe)
ensure non-worsening situation to adjoining properties
TOP CONDUIT RL: 108.04
‘SEWER RISING MAIN POTHOLE
new fence
- Sewer connections to be confirmed (Subject to Unitywater Approval)
- Water to new buildings (Subject to Unitywater Approval)
- Electricity to new building clear of water and sewer lines (Subject to Operational Works Approval)
- Stormwater for new building to include a 5k Litre above ground water tank for detention of new building
roof area directed to existing field inlet within Opal St (Subject to Operational Works Approval)
- All other stormwater from driveways and hardstand areas to be directed to landscaping areas to
50,209mm 172° 1" 2" SEWER RISING MAIN POTHOLE __|
‘TOP CONDUIT RL: 108.01
~~ Proposed
Lot 2
LL SEWERRISING MANPOTHOLE
‘TOP CONDUIT RL: 107.96
APPROVED PLANS
MCU19/0013 & RAL19/0003
NOOSA COUNCIL
9 MAY 2019
Scale 1:300
10,089mm 262° # 2"
US SEWERRISNG MAN
Son
SEWER COVPLED ONLY
0 1 2 3 4 5m
Site, Subdivision and
Preliminary Services
Layout Plan
Date: 29/01/2019
Documentiieilihe 2086BAN2 0808396
Version: 2\/esision!Dattes By UBD 12/01/2019
Print Date: 13 May 2019, 4:45 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.