Original source · versioned page text
Mcu
Attached to the e-mail MCU19/0013 - Withdraw Representations.
Noosa Council documents
450|, 16660 690|, [450
220 70 70 7 70 70 90 220 FLOOR AREAS:
3300 ool, 1950 _ || 950 1830 || 1500 [| 1400 |) 4250 LL 450
70 17 DWELLING 154.18 m?
2230 __ || 1000 3570 2 GARAGE 38.65 m?
220 2
Tl 1000 |} 10860 LL 920 | PORCH 2.52 mi ,
TH | Total 195.35 mi
L450
L450
8 Fone 061g atSSGD aie PGS og r WALL LEGEND
t it EXTERNAL WALLS
zy MASONRY VENEER
- 70mm TIMBER STUD FRAME
220
loath 1450¢!
| 900
° - 10mm PLASTERBOARD LINING [GENERAL]
Ss - 6mm VILLABOARD LINING (WET AREAS)
== -LINEA-BOARD CLADDING {UNO}
- 70mm TIMBER STUD FRAME (UNO)
- 10mm PLASTERBOARD LINING [GENERAL]
- 6mm VILLABOARD LINING (WET AREAS)
INTERNAL WALLS
<== - 70mm TIMBER STUD FRAME (UNO)
- 10mm PLASTERBOARD LINING [GENERAL]
a - 6mm VILLABOARD LINING (WET AREAS)
REFER TO ENGINEERS DETAILS FOR
ARTICULATION JOINTS IF REQUIRED
LEGEND:
Cl DENOTES- 112x112 TIMBER POST
BATH
wetties |
2290
2290
3220
3470
1518
3470
3910
2500
1270 |, 930 | 1270
a
720cs
/
ino
70
2640
pechven —t T
o
BED 2 \Os8 /O CH2700mm ENTRY 7 etoom eh
FAMILY [sconce | | (Js
laminate STORAGE ||g20cs,. “+4 UL
1530
1030
1630
| 1350 [70
3800
7
11400
3200
1518
=
220), |,
1
50
7
7
11400
© DENOTES - PHOTOELECTRIC SMOKE ALARM TO
BCAVOL 23.7.2 & AS 3786
© DENOTES- GAS BOTTLE/HWS LOCATION AS PER
Ww AS 5601
70
7420
DINING
Taminate
@ DENOTES- WHIRLY BIRD ON ROOF
5890
5890
3450
6320
5700
6140
GARAGE [ 7}
‘concrete © DENOTES- SKYLIGHT
3200
1518
3800
FLOOR PLAN NOTES:
TERMITE PROTECTION IS TO BE PROVIDED IN
ACCORDANCE WITH PART 3.1.3 OF THE BCA VOL
AND AS 3660.1
3000x900)
|
|
70
io |)
1
00],
30mm sgd rebate
220
“ 2438SGD dp Ps TET -2418SGD GXG)
PROVIDE A STATEMENT OF PROTECTION METHOD
FROM A TERMITE MANAGEMENT
PROFESSIONAL IN CONJUNCTION WITH THESE
DRAWINGS AT THE TIME OF SUBMISSION FOR
BUILDING APPLICATION APPROVAL.
220
450,
1
450|,
70 70 70 220
3300 1070 | 6380 2240 || 2100 sd | 6i0 TOILET DOORS TO BE PROVIDED WITH LIFT-OFF
APPROVED PLANS 2130 _ 1100 : 7480 veto seeesr6 WINDOWS AND DOORS ARE
221 70
MCU19/0013 & RAL19/0003 sa00 | 4270 Lino 6020 | [220 AS PER BUILDERS SPECIFICATIONS UNO
CONSTRUCTION IS NOTTO COMMENCE PRIOR TO
NOOSA COUNCIL 450/ 17350 q 1 Laso FULL APPROVAL BEING GRANTED IN WRITING BY
9 MAY 2019 | 7 THE CERTIFIER AND LOCAL AUTHORITY
MECHANICAL VENTILATION TO BE IN
ACCORD. WITH THE BCA PART 3.8.5 & AS 1668.2
»\, LOWER FLOOR PLAN GAS BOTILE LOCATION AS PER AS56O1
100 20mm STONE BENCHTOPS THROUGHOUT
THESE DRAWINGS AND DESIGN ARE
COPYRIGHT AND WILL NOT BE USED
fy OR REPRODUCED BY ANY MEANS
——— | | (oe) wtouty on parm without PRIOR
G G rdn HOMES SSE) WIRIITEN PERMISSION FROM
J. 7 a. er, GJ GARDNER HOMES 7
Sunshine Coast North [50 Nor scate FROM THIS DRAWING x SCION ORANG CLIENT LOCATION ae cl -
21171 Noosa Eumundi Rd PH: 07 54 702324 VERIFY ALL DIMENSIONS PRIOR TO E 7 [RH IA A ERHARTER, Robert LOT 6 ON RP82318 INDICATED a
Noosaville , Qld COMMENCEMENT OF ANY SITE WORKS 10 OPAL LANE DRAWING FILE NUMBER] PAGE
[AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN COOROY, QLD GJGSCN190173 3
pen PROJECT JOB SPECIFICATION BY BUILDER TAKES | DATE
PROPOSED RESIDENCE PRECEDENCE OVER THESE PLANS LOWER FLOOR PLAN
CUSTOM. CLIENT SALES CHRIS McNEIL PROJECT STATUS
CONSTRUCTION DRAWINGS
SCALE HEETSIZE] CLASS | WIND | ISSUE
Docume: Hy 19
Wetion’ 2 Merson Dates 36/08/2019 Print Date: 13 May 2019, 4:45 PM