Council archive · source document
Updated Plans - GIA - received 21.3.24 · MCU22/0172.02
Plans and drawings: the text below has words only, no drawings.
D C
05-02 05-02
A B C D
5,940 8,950 1,900
GATE
SCR-04
G07
A/C
RL 24.380 GATE
RL 23.900
TOW 27.460 TOW 26.220 RL 23.420
SOUTH
SCR-04
CON-01
G08
04-02
CON-01
PAV-01
265mm
04 03 02 01 03 02 01 03 02 01 04 03 02 01
STEP
01 GARDEN
01
PLANTER
FALL
POOL DECK
1,200
1,200
FWG
FFL 25.460 LINE OF FLOOR OVER CHS POST
LIFT LINE OF FLOOR OVER
1260
RL 26.460 TIMBER POST
ZERO CORNER W08 W09
CHS POST
02 02
930
PT-02
EPD
BLOCK WALL
SHS POST
POOL
LINE OF FLOOR
LINE OF FLOOR
B FWG
PT-01 B
1265mm
UNIT 02
FALL FALL
OVER
OVER
05-01 05-01
LINE OF FLOOR OVER
175mm
STEP
STEP
LINE OF TIMBER PERGOLA OVER
W07
GARDEN
FFL 25.195 TERRACE DINING LIVING TERRACE
3,778
3,778
CON-02 CON-02 CON-02 CON-02
W10
1000 HIGH WALL 400 HIGH WALL
FFL 25.020 FFL 25.020 FFL 25.020 FFL 25.020
STEPPERS
PAV-01 KITCHEN
CON-02
D08
01
CLOTHESLINE
PTY FR NCC 2019
03 POOL EQ.
G06 FFL 25.020 SHS POST
Compliance 3.10.7
FIRE-01
03
POOL EQUIP
07 06 05 04 03 02 01 BBQ TF-01
14
18
16
15
13
12
10
17
11
176mm STEP
PDR
4
9
8
6
5
3
2
7
UNDER CON-02 RAISED STEP
SHS POST
1,367
1,367
FWG WEST
1200 HIGH GATE
D07
ACCESS UNDER PT-01 04-01
AC STAIRS UP FROM BELOW
TO SERVICES
DP-01
04 TOW 28.260 EAST
04-02
04
DP-01
14
16
15
13
12
10
17
11
4
9
8
6
5
3
2
7
ACCESS UNDER
1
176mm STEP
TO SERVICES PT-01
D06
CLOTHESLINE
1,367
1,367
PDR STAIRS UP FROM BELOW
POOL EQUIP BBQ FWG FFL 25.020 SHS POST TF-01
UNDER HEAT PUMP RAISED STEP
07 06 05 04 03 02 01 CON-02 FIRE-01
POOL EQ.
05 G05
SHS POST NCC 2019 05
PTY FR Compliance 3.10.7
D05 01 1000 HIGH
BALUSTRADE
LINE OF TIMBER PERGOLA OVER
1200 HIGH GATE
FALL
KITCHEN
CON-02
UNIT 01 FALL
STEPPERS
PAV-01
W03
TERRACE DINING LIVING TERRACE
BAL-02
3,778
3,778
W06
CON-02 CON-02 CON-02 CON-02
GARDEN
POOL DECK FFL 25.195
FFL 25.020 FFL 25.020 FFL 25.020 FFL 25.020
LINE OF FLOOR
LINE OF FLOOR
RL 26.460
1265mm
BLOCK WALL
175mm
STEP
STEP
POOL
OVER
OVER
PT-02 A
LINE OF FLOOR OVER
PT-01 05-01
SHS POST
EPD
FWG ZERO CORNER
06 CHS POST
930 06
W05 W04
CHS POST TIMBER POST
1,200
1,200
LIFT
1260
PLANTER LINE OF FLOOR OVER LINE OF FLOOR OVER
FALL
FWG
FFL 25.460
07 GARDEN
07
265mm
PAV-01 04 03 02 01 03 02 01 04 03 02 01 03 02 01
STEP
RL 24.398 RL 23.926 RL 23.297
SCR-04
GATE CON-01
G03
NORTH CON-01
TOW 27.460 TOW 26.220
04-01 CON-01
EAST A/C
#LayID
SCR-04
G04
GATE
5,940 8,950 1,900
D C
A 05-02 B 05-02 C D
1. GENERAL ARRANGEMENT MID LEVEL
- Scale 1:50
notes : issue amendment log by date
project: north date: 19/03/24
15 BUILDING APPROVAL PP 31-08-23
1 The designs, drawings and specification are copyright and always
remain the property of Archend.
16 ISSUE FOR BA RFI JJ 14/09/23 PROPOSED DUPLEX, drawn: JJ
2 Before commencing construction:
17
18
ISSUE FOR BA RFI
ISSUED FOR INFORMATION
JJ
JJ
20/09/23
19/10/23
22 GRANT STREET, NOOSA HEADS, QLD 4567 checked: MS
-Verify all dimensions and levels.
19 ISSUED FOR CONSTRUCTION JJ 24/11/23 client: scale @ A1 : 1:50
-Verify location and levels of all services on site.
-Verify that floor levels and finished levels will enable connection to
20 ISSUED FOR CONSTRUCTION JJ 14/12/23 INTEGRA PARTNERSHIPS scale @ A3 : 1:100
21 ISSUED FOR CONSTRUCTION JJ 22/02/24 [email protected]
services.
22 ISSUED FOR CONSTRUCTION JJ 14/03/24 title: project/drawing no. sheet: A1
3 Do not scale this drawing. When in doubt refer to Designer. QLD. QBCC: 15226654
4 SCALE 1:50 1:50
MID LEVEL FLOOR PLAN
23 ISSUED FOR CONSTRUCTION JJ 18/03/24
24 ISSUED FOR CONSTRUCTION JJ 19/03/24 D22-056_A02-02_24
GSPublisherVersion 399.0.95.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
07 06 05 04 03 02 01
1,200 3,778 1,367 1,367 3,778 1,200
1,570
SCREEN
HEK-02 HEK-02 HEK-01 HEK-01
PARAPET LEVEL PARAPET LEVEL
RL 31.420 RL 31.420
BLK-01 BLK-01
SCR04 SCR04
700
700
P2 P2
UPPER LEVEL CEILING UPPER LEVEL CEILING
RL 30.720 RL 30.720
HEK-01
BOUNDARY
BOUNDARY
SLIDING
SCREEN
BLK-01
P4 W22 W21
2,700
2,700
UPPER LEVEL UPPER LEVEL
RL 28.020 RL 28.020
TIMBER PERGOLA TIMBER PERGOLA
SP SP
TIMBER POST W03 FIRE-01 FIRE-01 W10 TIMBER POST
3,000
3,000
TOW 26.020
FC-01
BAL-02 P2
RL 25.020 FC-01 P2
MID LEVEL BLK-01 BLK-01 MID LEVEL
RL 25.020 P2 RL 25.020
CONC-02 CONC-02 P2
BLK-01 G08
G03
P2
SCR04 SCR04
D01 STEEL WIRE STEEL WIRE D04
2,920
2,920
TRELLIS TRELLIS
GARAGE GARAGE
DOOR DOOR BLK-01 BLK-01
BLK-01 BLK-01
FINISH BLK-01 FINISH P1 P1
P1 P1
P4
LOWER LEVEL LOWER LEVEL
RL 22.100 RL 22.100
LB LB
1 WEST ELEVATION
- Scale 1:50 A B C D
5,940 8,950 1,900
SCR-04 SCR-06 HEK-02
RL 31.420
PARAPET LEVEL PARAPET LEVEL
RL 31.420 RL 31.420
BLK-01 BLK-01 BLK-01
700
700
UPPER LEVEL CEILING P2 P2 P4 UPPER LEVEL CEILING
RL 30.720 RL 30.720
BOUNDARY
BOUNDARY
W14
SCR-04 SCR-06 SCR-04
2,700
2,700
TOW 28.260
RL 28.020
UPPER LEVEL UPPER LEVEL
RL 28.020 TIMBER PERGOLA RL 28.020
BLK-01 BLK-01
TOW 27.460
P2 P4
TIMBER
1,800
BLK-01 SHS FIRE-01
POST
P2 W04 BLK-01
W05
BLK-01 BBQ - REFER JOINERY P4
FC-01
P2 PF-01 DRAWINGS
3,000
3,000
200
P2 BLK-01
P2 TOW 26.020
SP SP
1,000
POOL
BLK-01
1,000
BLK-01 TOW 25.195 CONC-02 P2
265
P2
MID LEVEL MID LEVEL
RL 25.020 RL 25.020
175
G03
CONC-02
2,920
2,920
LIFT TO RL 23.297
LOWER
LEVEL BLK-01
BEYOND P1
LOWER LEVEL LOWER LEVEL
RL 22.100 RL 22.100
2 NORTH ELEVATION
- Scale 1:50
notes : issue amendment log by date
project: north date: 19/03/24
07 ISSUE FOR REVIEW HC 30-05-23
1 The designs, drawings and specification are copyright and always
remain the property of Archend.
08 COORDINATION ISSUE HC 06-06-23 PROPOSED DUPLEX, drawn: JJ
2 Before commencing construction:
09
10
CONTRACT ISSUE
BUILDING APPROVAL
HC
PP
09-06-23
31-08-23
22 GRANT STREET, NOOSA HEADS, QLD 4567 checked: MS
-Verify all dimensions and levels.
11 ISSUE FOR BA RFI JJ 14/09/23 client: scale @ A1 : 1:50
-Verify location and levels of all services on site.
-Verify that floor levels and finished levels will enable connection to
12 ISSUE FOR BA RFI JJ 20/09/23 INTEGRA PARTNERSHIPS scale @ A3 : 1:100
13 ISSUED FOR CONSTRUCTION JJ 22/02/24 [email protected]
services.
14 ISSUED FOR CONSTRUCTION JJ 14/03/24 title: project/drawing no. sheet: A1
3 Do not scale this drawing. When in doubt refer to Designer. QLD. QBCC: 15226654
3 SCALE 1:50 1:50
ELEVATIONS
15 ISSUED FOR CONSTRUCTION JJ 18/03/24
16 ISSUED FOR CONSTRUCTION JJ 19/03/24 D22-056_A04-01_16
GSPublisherVersion 399.0.95.0