                        Pedestrian and Bicycle Facilities
                 46.    Pedestrian and bicycle facilities must be provided for the development. The works must
                        be undertaken in accordance with an Operational Works approval and must include in
                        particular:
                        a.      the development must include 19 bicycle spaces as shown on the approved plans;
                                and
                        b.      adequate separation of all specific pedestrian routes from vehicle access and
                                manoeuvring areas, and clear demarcation by pavement marking, signposts or
                                changes in surface materials or levels.
                        Public Safety
                 47.    During operating hours, all parking areas, pedestrian areas and entrances/exits to all
                        stairwells, lifts, foyers and public toilets must be well lit with vandal resistant lighting and
                        with intensities to satisfy the requirements of Australian Standard AS1158 “Public
                        Lighting Code”. Lighting must be designed to reduce the contrast between shadows and
                        well-lit areas. In particular, appropriate security lighting must be provided in the location
                        of the bicycle/ scooter parking and bin storage area.
                 48.    After hours access to loading docks, storage areas and the basement carpark (including
                        the vehicle ramp and all stairwells) must be restricted by a security gate, lockable doors
                        and/or other suitably appropriate means. The basement carpark must be kept closed
                        and locked at all times while the use is not operating.
                        Stormwater Drainage
                 49.    The site must be provided with a stormwater drainage system connecting to a lawful
                        point of discharge. The works must be undertaken in accordance with an Operational
                        Works approval, be generally in accordance with RECOR’s Stormwater Management
                        Plan (20230025-SWMP01, Rev. 01) dated 30 May 2024 and the Queensland Urban
                        Drainage Manual.
                 50.    A stormwater quality treatment system must be provided for the development. The works
                        must be undertaken in accordance with an Operational Works approval and Water by
                        Design’s Bioretention Technical Design Guidelines 2014, and must include in particular:
                        a.      stormwater quality treatment devices of a size and location generally in
                                accordance with those shown in RECOR’s Stormwater Management Plan
                                (20230025-SWMP01, Rev. 01) dated 30 May 2024.
                        b.      bioretention device(s) which:
                                  a.   are design generally in accordance with IPWEAQ Standard Drawing DS-
                                       073, DS-075 and DS-076; and
                                  b.   are provided with a free-draining outlet from the sub-soil drainage system.
                 51.    The development shall be provided with approved permanent signage to educate the
                        public on the function of the bioretention basin. The wording for the signage for the
                        bioretention basin is to include: “BIORETENTION BASIN – This bioretention basin
                        reduces the pollution of our waterways by reducing the amount of heavy metals, litter,
                        suspended solids, and nutrients discharged to the Noosa River”.
                 52.    All bioretention basins must be maintained in accordance with Water by Design’s
                        Maintaining Vegetated Stormwater Assets (Version 1) 2009. Records of all maintenance
                        activities undertaken must be kept and made available to Council upon request.
                 53.    All proprietary stormwater quality treatment devices must be routinely checked, serviced
                        and cleaned in accordance with the manufacturer’s recommendations. Records of all
                        maintenance activities undertaken must be kept and made available to Council upon
                        request.




                                                                                                            Page 10 of 19
Document Set ID: 23655142
Version: 6, Version Date: 27/03/2025

Used in these records

About this file

File size
225 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - Council Meeting Decision MCU24 0074.pdf · 225 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.