Council archive · source document
Decision Notice - Council Meeting Decision MCU24 0074 · MCU24/0074
Any repair work which proposes to alter the alignment or level of existing services and
assets must first be referred to the relevant service authority for approval.
Acid Sulfate Soils
68. A preliminary site-specific Dewatering and Acid Sulfate Soils Management Plan must be
prepared and submitted as part of a future Operational Works application for the site.
The Dewater and Acid Sulfate Soils Management Plan must be prepared by a suitably
qualified person and include, but not be limited to:
a. testing, monitoring and treatment requirements for the works in accordance with
the National Acid Sulfate Soils Guidance; and
b. demonstrate how groundwater encountered during excavations and ongoing
operations of the basement will be managed.
Demolition Works
69. Unless specifically conditioned otherwise, all works must comply with the relevant
acceptable solutions as contained in the Waste Management Code and Water Quality
and Drainage Code of the Noosa Plan 2020.
70. Demolition must be undertaken in a manner that causes no detrimental effect upon the
amenity of the neighbourhood by reason of the creation of excessive noise, lighting, air-
borne hazards, atmospheric pollutants (including dust or odours) nuisance or any other
emissions in accordance with the nuisance provisions of the Environmental Protection
Act 1994.
Treatment of Temporarily Vacant Land
71. Where some or all of the land remains vacant or undeveloped for more than 3 months,
or buildings are demolished and redevelopment is delayed for more than 3 months, the
following works must be carried out:
a. the site must be cleared of all rubble, debris and demolition materials
b. the site must be graded to prevent ponding (to the same level as the adjoining
footpath wherever practicable), turfed and mown at a minimum 3 weekly intervals
c. the site must be landscaped with perimeter planting consisting of advanced
specimens of fast growing tree species
d. the site must be maintained to ensure no nuisance to adjacent premises, roads or
footpaths
e. where fencing is installed to secure boundaries:
i. the fencing must be durable and not capable of being pushed or blown over
ii. the fencing type must not detract from local amenity (barbed wire is not
acceptable)
iii. vandalism must be promptly repaired, and any graffiti removed.
Health and Safety
72. All building materials containing asbestos, including asbestos cement sheeting or
roofing and lagging, are removed from the building prior to demolition or relocation.
73. Removal of building materials containing asbestos must be undertaken by a licensed
asbestos removalist.
74. Asbestos removal work (Section 466) of the Work Health and Safety Regulation 2011
requires a licensed asbestos removalist to give notice to Workplace Health and Safety
Queensland (WHSQ) of licensed asbestos removal work at least five days before the
work commences. Notification must be made using Form 65: Notification of licensed
asbestos removal work, demolition work or emergency demolition.
Page 13 of 19
Document Set ID: 23655142
Version: 6, Version Date: 27/03/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - Council Meeting Decision MCU24 0074.pdfRelated documentApplication case desk ↗
About this file
- File size
- 225 KB (small file)
- File type
No other editions are linked here.