GENERAL COMMITTEE MEETING AGENDA 29 JUNE 2015
REPORTS DIRECT TO GENERAL COMMITTEE
1 FURTHER REPORT - REQUEST TO CHANGE CONDITIONS OF AN EXISTING
MATERIAL CHANGE OF USE APPROVAL FOR A MIXED USE DEVELOPMENT AT 90
GOODCHAP STREET, NOOSAVILLE (07/0012)
DOCUMENT INFORM AT ION
Author Development Planner, Jack Lewis
Planning & Infrastructure Department
Index ECM / Application / 132007.12.6
Attachments Nil
ALTERNATIVE RECOMMENDATION
That Council note the report by the Development Planner to the General Committee Meeting
dated 29 June 2015 regarding Application No. 132006.12.6 for a Change to an Existing Approval,
situated at 90 Goodchap Street, Noosaville and:
A. Change Condition 1, 7, 8, 10, 12, 36, 38, 64, 65 & 66 to read:
1. Development undertaken in accordance with this approval must generally comply
with the approved plans of development. The approved plans are numbered Site
Plan Overall Parking Layout 0427 DA01E, Site Plan Overall Podium Level 0427
DA02E, Site Plan Overall Upper Plan 9427 DA03E, Stage 2 Carpark Plan 0427
DA04E, Stage 2 Podium Plan 0427 DA05E, Stage 2 Upper Floor Plan 0427 DA06E,
Roof Plan 0427 DA07D, Existing Approved Elevation & Sections 0427 DA08D,
Proposed Elevations & Sections 0427 DA09D, Proposed Carpark Lower Level Plan
0427 DA10E, Proposed Carpark Mid Level Plan 0427 DA11E, Proposed Carpark
Upper Level Plan DA12E and Proposed Carpark Elevations & Sections 0427 DA13E
prepared by Middap Ditchfield Pty Ltd and dated May 2007 and Working Drawings
Carpark Layout 0715 WD01.1 prepared by Middap Ditchfield Pty Ltd and dated April
2008 and Plan of Lots 4, 5 & Emt D (Restricted) in Lot 4 SP 196846 prepared by
Jones Flint & Pike and as may be amended by these conditions.
7. Secure bicycle racks shall be provided on site to accommodate a minimum of 35
bicycles. The proposed bicycle racks shall be identified on the plans submitted for
Operational Works approval and shall be located to the reasonable satisfaction of the
Council.
8. End of trip facilities shall be provided within the approved buildings at a minimum rate
of 18 lockers and 3 showers.
10. The proposed development shall not exceed a maximum height of:-
10.1 for buildings, 2 storeys and 10 metres above natural ground level, with the
exception of building B, which may be 3 storeys in height in accordance with
the approved plans.
10.2 for the car park structure, 8 metres above natural ground level, with the
exception of the rendered block work up stand (ie. lift overrun) adjacent to
the driveway ramp which shall not exceed 10.5 metres above natural ground
level.
12. The development is permitted a total maximum use area of 6,054m2 with each
individual use permitted the following maximum use areas at any one time:-
12.1 Commercial Business – Type 1 Office – 2420m2
12.2 Commercial Business – Type 2 Medical – 3000m2