Performance outcomes                                   Acceptable Outcomes                                    Compliance
                                                       and cross-over is provided on the frontage with the
                                                       lower order.

                                                       AO14.3                                                 Not relevant to this application.
                                                       For corner lots, driveways and crossovers are
                                                       located in accordance with Council's standard
                                                       drawings.

                                                       AO14.4                                                 Complies with A014.4
                                                       If in the Rural zone or Rural Residential zone, the    The driveway is not located in road reserve however has been
                                                       driveway and cross-over is located to provide          located to achieve safe sight distances.
                                                       minimum safe sight distances in accordance with
                                                       Austroads.

                                                       Editor's Note - An operational works application is
                                                       required for a second driveway.
Bushfire Hazard Management                                                                                     Complies with A015
PO15                                                    AO15                                                   The site is located within a Potential impact buffer area and has
Where located in a Bushfire Hazard Area as shown        Within a bushfire hazard area where there is no        access to on-site water tanks and a swimming pool for firefighting
on the Bushfire Hazard Overlay Map in Schedule 2        reticulated water supply, the premises has:            purposes. The secondary dwelling will also be provided with a
and not in a water service area, an adequate, reliable,                                                        tank for water supply and will also be fitted with a standard fire
safely located and freely accessible water supply is     1. an accessible dam, swimming pool or water          brigade fitting.
provided for fire fighting purposes, which is in              tank available for firefighting purposes with an
addition to day to day water supply.                          onsite water volume of not less than 5,000
                                                              litres; and
                                                         2. a water supply outlet pipe 50 millimetres in
                                                              diameter and fitted with a standard fire
                                                              brigade fitting connected to the water supply
                                                              (other than where the water supply is in a
                                                              swimming pool or dam).

                                                       Editor’s Note — Water supply capacity for
                                                       firefighting purposes is in addition to water supply
                                                       capacity for household use.
Flood Hazards                                                                                                  Not relevant to this application.
PO16                                                   AO16.1                                                  The site is not located in the Flood Hazard Area.
Development is designed and sited to ensure risk to    Where the development is located in the Flood
people and property from flooding is avoided or        Hazard Area as shown on Flood Hazard Overlay
minimised.                                             Map in Schedule 2,
                                                       the finished floor level of habitable rooms is at least
                                                       300 millimetres above the Defined flood event
                                                       (DFE).
Log in to download the original file

Information Response.pdf · 9.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.