Information Response
Performance outcomes Acceptable Outcomes Compliance
windows of habitable rooms face away from
the infrastructure.
Earthworks and Drainage Not relevant to this application.
PO21 AO21 Minimal earthworks are proposed. The proposed secondary
Earthworks and drainage operational works do not Filling other than accessways: dwelling will be transported to the site and sits on a stumps.
directly, indirectly or cumulatively cause adverse
impacts external to the development site by: 1. does not extend more than the equivalent of
3 metres around the main building, measured
1. causing ponding of water on the site or nearby from the outer walls of the building;
land; 2. is limited to a maximum of 500m2; and
2. increasing flooding, which adversely affects the 3. does not impact on the local drainage of
safety or use of any land upstream and adjoining properties.
downstream;
3. adversely affecting the flow of water in any
overland flow path; and
4. adversely affecting the privacy or visual amenity
of surrounding property.
Editor's Note—Development should ensure that
filling does not impact on the amenity and usability
of neighbouring properties (including loss of privacy
caused by relative level changes) or offsite drainage.
Landslide Hazard Area Not relevant to this application.
PO22 AO22.1 The proposed secondary dwelling, including associated access is
Development maintains the safety of people, Development, including associated access, is not located outside the moderate, high and very high landslide hazard
property and hazardous materials stored in bulk located on land identified as a landslide hazard areas on the Landslide Hazard Overlay Map. Please refer to
from the risk of landslide. area on a Landslide Hazard Overlay Map. Drawing No 21038.01D, Sheet 3 of 4 at Attachment 1 for
confirmation.
AO22.2
Development, including associated access, is
located outside moderate, high and very high
landslide hazard areas and areas with 15% slope or
greater, as determined by a site-specific slope-
analysis.
Editor's Note—A site- specific geotechnical
assessment may be used to demonstrate that
although the proposed development is shown on
the Landslide Hazard Overlay as being in the
moderate, high or very high landslide hazard area,
the landslide risk is low or very low.