    BUNNINGS WAREHOUSE, NOOSAVILLE
    SURFACE WATER MANAGEMENT PLAN
                                                                                       C"*) Cardnly

t              For the purposes of the modelling, sensible device parameters based on outline quantity
               calculations were input to the model, as described in the table below. If the layout of the
               site changes in future these can be amended to suit, providing that the overall effectiveness
               is maintained. The bio-retention device is modelled as a single large device, for example,
               where in fact several smaller devices of equal total capacity would be employed in the car
               park landscaping divides around the site.

               Table 11         Bioretention Device Parameters



I
                 Parameter                                                      Value

                 Surface Area (m)                                               860

                 Extended Detention Depth (m)                                    0.1

                 Filter Area (m)                                                860

                 Filter Depth (m)                                                0.5

                 Mean Particle Diameter (mm)                                    0.36

                 Saturated Hydraulic Conductivity (mm/hr)                       180

                 Overflow Weir Width (m)                                          2


               Rainwater tanks provide some reduction in nitrogen loads, thought to be via biofilm activity
               within the tank. The reduction in overall runoff through storage and reuse will also minimise
               loads at the site outlet. To enable a conservative quality assessment, only a nominal
               rainwater tank size was used, having a volume of 18kL and a surface area of 8m2. A
               realistic re-use demand of 1250kL per year was applied. This size is conservative given
               the likely rainwater tank size to be adopted (refer Section 5).

               4.8             Modelling Results
               The results of the MUSIC modelling, shown as total annual loads, are presented in the
               table overleaf. It can be seen from the tables that the treatment train would reduce all of
               the total loads released from the developed site to such an extent that the target reductions
               are achieved for all pollutants.

               Table 12         Total Annual Loads

                                            Total Suspended            Total             Total       Total Gross
                            Situation
                                                 Solids             Phosphorus          Nitrogen      Pollutants

                       Existing Site
                                               3,000 kg/yr            6.27 kg/yr        34.1 kg/yr     196 kg/yr
                       (Rural Res)

                      Development
                                               6,880 kg/yr            18.5 kg/yr        106 kg/yr      683 kg/yr
                       Potential

                   Development with
                                                1240 kg/yr            5.20 kg/yr        54.8 kg/yr      0 kg/yr
                     treatment train
                  Realised Reduction              82 %                   72 %             48 %          100 %

                  Target       Reduction          80 %                   60 %             45 %           90 %


               Note that the proposed development, owing to its water sensitive urban design
               measures, produces lower annual pollutant loads than the existing rural residential
               case, for most of the modelled pollutants.


t
    Bunnings Warehouse                                     Version 1                                 15 December 2006
    J.\3501-54\WP\SWMPdoc                            Commercial in Confidence                                 Page 13

Used in these records

About this file

File size
10.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request to Change Current Application.pdf · 10.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.