     RUNNINGS WAREHOUSE, NOOSAVILLE
     SURFACE WATER MANAGEMENT PLAN                                                            C"*-) Carla/no

     5.            IRRIGATION TANK SIZING

                   Historical rainfall data was obtained for Noosa for the period between 1950 and 2002. A
                   yield analysis was conducted, applying the rainfall to the building roof area (accounting for
                   a first flush loss of 0.2mm and an initial loss of 1 mm) to estimate the daily inflow to the tank.

                   The roof area was assumed to be 4600 m2, derived from initial design drawings. In many
                   instances, the fall of the roof and surrounding ground levels dictate that not all of the
                   rainwater can be practicably harvested - for this reason a `half-sized' roof of 2300m2 was
                   also modelled.
11
                   Demands of 2500, 3000 and 3500 litres per day were used. Over a nursery area of
                   approximately 1000 m2, this equates to an irrigation rate of about 2.5, 3.0 and 3.5 mm per
                   day.

                   The model provides an estimate of the demand supplied, expressed as a percentage of the
                   total volume required. Note that it is not a percentage of total time the demand is supplied
                   - although this figure will be similar. The results are shown in Table 13 below.

                   Table 13     Rainwater Tank Performance
                                                          Demand supplied (%) for each tank size (kL)
                     Dema n d : roof a rea
                                              10   20      30         40   50   60       70    80   90    100      150     200

                      2500 Lpd:4600m2         64   79      87         91   94   95       96    97   98    99       100     100
                      3000 Lpd:4600m2         59   74      83         88   91   93       94    96   96    97       99      100
                      3500 Lpd:4600m2         56   70      79         84   88   91       92    94   95    96       98       99

                      2500 Lpd:2300m2         60   75      83         87   90   92       94    95   96    97       99      100

                      3000 Lpd : 2300m2       55   70     78          83   86   89       91    92   93    94       97       99

                      3500 Lpd:2300m2         52   65     73          78   82   85       87    89   90    91       95       97


                   The results are better presented as a graph, as follows:


                                                   Rainwater Tank Performance

                          100

                           95
                           90
                           35                                                                              2500 Lpd. full roof
                                                                                                           3000 Lpd, full roof
                                                                                                           3500 Lpd. full roof
                                                                                                           2500 Lpd, half roof
                                                                                                           3000 Lpd, half roof
                                                                                                           3500 Lpd, half roof




                                             50                 100                150              200

                                                         Tank Size (kL)




     Runnings Warehouse                                       Version 1                                         15 December 2006
     J \3501 54^wp S iP tloc                            Commercial in Confidence                                         Page 14

Used in these records

About this file

File size
10.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request to Change Current Application.pdf · 10.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.