08/0169 - Response to Information Request [As Published] · 132008.169
From the proposed building plans and survey information the construction of the garage floor level will require a cut in the order of 2.6 - 3m below the existing surface level adjacent the southern boundary. For this to be achieved a cantilevered or tied cantilevered retaining wall must be installed. We recommend that either augered secant or contiguous concrete pile systems be used to achieve this. The use of driven sheet piling is not recommended in this area. Pre-Augered and pushed in sheet piles would be an acceptable alternative. The design of the retaining system is to be by a specialist contractor and must consider surcharge loading from sloping embankments above the structures. Vegetation removal should be minimised. As soon as possible after construction, dense, deep rooted native vegetation cover should be propagated on any exposed surface in order to stimulate and improve the binding properties of the natural vegetation. 7.4 Stormwater All stormwater collected within the allotment must be disposed of in a manner that does not compromise the stability of the site. Where possible roof drainage must be directed to and disposed of via the access easement that serves the allotment. All other stormwater including surface runoff must be collected via approved means and stored in tanks for re-use. Overflow from the tanks should be via infiltration pits to minimise surface flows and scour. We have compiled a stormwater drainage plan detailing these proposals and attached a copy to this report (Drawing No. 19064-SW1). 8.0 CONCLUSIONS: Based upon our findings and recommendations we believe the allotment in its current state is stable and would support the residential construction within the scope of the current proposals and AS 2870- 1996. The use of vibrating earthwork equipment used for driving piles is not advised within the allotment. Mini excavators or similar excavation equipment would be acceptable for use throughout construction. Any removal of existing vegetation should be followed by reinstatement of deep rooted native vegetation common to the area. Measures to prevent sand migration during construction must be implemented. These must protect against wind blown and fluid (runoff) migration of the sands. Foundations must be designed in accordance with AS2870-1996 and accepted engineering theory. 9.0 DOCUMENTATION: In preparation of this report we have considered architectural and survey information contained within the proposed architectural plans as provided by Noel Robinson Architects and a site survey plan by Lau Surveys (No 6611-DT]). 10.0 STANDARDS AND REFERENCES: The standards and references used in compiling or referred to in this report are as follows: AS 1726-1993 Geotechnical Site Investigations AS 2870-1996 Residential Slab & Footings Code AS 1289 Methods of testing soils for engineering purposes AS 3798-1996 Guidelines on earthworks for commercial and residential developments. oecee SCG Consulting Engineers 4 SCG Ref: 19064(S)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0169 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 9.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.