    Division 13 – Driveways and Parking Code

    column 1                                    column 2
 Specific Outcomes                P   Probable solutions (if code assessable)
14.113 General
O1 Vehicular access does          S1.1 Vehicular access is located and designed
not adversely impact on safety,   in accordance with AUSTROADS- Guide to
capacity and operations of the    Traffic Engineering Practice requirements for
existing or planned road          sight distance and Section 3 of AS2890.1
network, the proposed             Parking Facilities;
driveway, cycleways or            AND
                                                                              22
pedestrian pathway systems.       S1.2 Only one footpath crossing is provided ;
                                  AND
                                  S1.3 Driveways, other than within any
                                  setback have a maximum grade in
                                  accordance with Section 3 of AS/NZS 2890.1


O2 Driveways                      S2.1 Design of the driveway across the             Complies – The proposed
and crossovers—                   footpath is in accordance with Council’s           development will comply with
a) are suitable and safe for      Standard Drawings 9002 or 9005 as                  this requirement, please refer
    their intended use; and       appropriate for the particular type of             to attached site plan and
b) match Council                  development as annotated on the drawings;          engineering drawings reflecting
    infrastructure.               AND                                                these details of compliance.

                                  S2.2 Driveways are designed and                    Complies – The driveway is
                                  constructed in accordance with Council             designed in accordance with
                                  Standard Drawings 9014, 9019, 9020, 9021,          Council Standard Drawings
                                  as appropriate for the particular type of          9014, 9019, 9020, 9021 to be
                                  development as annotated on the drawings;          consistent for the particular
                                  AND                                                type of development as
                                                                                     annotated on the drawings
                                  S2.3 The change in grades in the driveways
                                  and ramps is in accordance with Section 3 of       Complies – Please refer to
                                  AS2890.1 Parking Facilities.                       attached Building Design
                                                                                     Drawings

O3 In commercial zoned            S3.1 Design of multi-tenanted developments         N/A - The proposed
areas, the number of              in commercial zoned areas include shared           development is not located
driveways across pedestrian       driveways and parking areas;                       within a commercial zone.
footpaths is minimised.           AND
                                  S3.2 Driveways are located so they abut
                                  existing driveways of adjoining development
                                  where practicable and reciprocal easements
                                  are created to reduce the sealed driveway
                                  width.

O4 Vehicular access does          S4.1 Footpath and kerb crossings are located       Complies - The proposed
not adversely impact on the       clear of existing storm water inlet structures,    development driveways and
capacity, operations and          water and sewerage infrastructure fittings, any    crossovers comply. Please
maintenance of the existing       other exiting utility infrastructure, existing     refer to attached Building
infrastructure;                   landscaping and vegetation.                        Design drawings for details.
AND

                                                                                     Complies - Existing vegetation
O5 Vehicular access does          S5.1 No solution provided                          within the road reserve will be
not adversely impact on the                                                          retained to enhance proposed
integrity of existing                                                                onsite landscaping, except
landscaping or native                                                                where provision is made for
vegetation.                                                                          the driveway access points.




                                                                                    Building Suncoast Green       28
Log in to download the original file

4.0 Planning Report.pdf · 2.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.