Original source · versioned page text
AA1345BFIRE Revision 2
Attached to the e-mail MCU15/0109 - Response to Information Request - Email 6 of 6.
The original of this document is very large (13.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Extract from Noosa Plan
Section 13.31 Specific outcomes for the Natural Hazards Overlay Code
Table 13.9 Bushfire hazard areas
Column 1 Column 2 Column 3
Specific Outcomes Probable solutions Response
13.33 Effects of use and works
New Uses S4.1 The use is sited on The site is mapped under the
O4 The proposed use does land that is not in a Noosa Plan as Medium bushfire
not compromise the safety Medium or High Bushfire hazard area, however the site
or people or property from Hazard Area; has largely been cleared of
bushfire. OR mature vegetation and the
S4.2 The use is sited on majority of site vegetation will be
land that is determined as cleared to facilitate the
low bushfire risk by a site development.
specific bushfire hazard
assessment. Proposed buildings A, B and C
will be located in areas of low
hazard. Buildings D, E, F and G
which border the surrounding
vegetation are required to be set
back 19.5m (1.5 times the
predominant height of the
mature tree canopy). We
understand a minimum setback
distance of 13m will be available
with building construction to
comply with BAL29, to protect
property. A Bushfire
Management and Evacuation
Plan has been prepared for the
site to facilitate safe evacuation
in the event of an emergency.
Protection of S5.1 Community Uses Not applicable – residential
Infrastructure and and Infrastructure Uses development
Community Uses are not located in a High
O5 Community uses and or Medium Bushfire
Infrastructure Uses, Hazard Area identified on
including that identified Overlay maps OM1.4 to
below, are able to function OM9.4;
effectively during and OR
immediately after bushfire S5.2 Building work will not
events- involve more than an
a) Emergency service additional 20m2 of gross
facilities; floor area to an existing
b) Hospitals; building;
c) Education Type 4 uses, OR
including stores for S5.3 Where located in a
valuable records or items of High or Medium Bushfire
historic or cultural Hazard Area identified on
significance; and Overlay Maps OM1.4 to
d) Service and utility uses, OM9.4, uses are designed
including electricity to function effectively
substations, major electrical during and immediately
depots and water treatment after bushfire events.
AA1345BFIRE Rev. 2 Page 1 of 3