plants.
Hazardous Materials S6.1 Hazardous material Not applicable – proposed
O6 Public safety and the are not manufactured and development is residential
environment are not stored on site.
adversely affected by the
detrimental impacts of
bushfire on hazardous
materials manufactured or
stored in bulk.
13.34 Siting, design and construction
O7 Uses and works S7.1 Uses and works Proposed buildings A, B and C
including building works are including building works will be located in areas of low
site, designed and are sited- hazard. Buildings D, E, F and G
constructed to- a) on lots greater than which border the surrounding
a) minimise the number of 2500m2; vegetation are required to be set
people ad property subject i) in locations of lowest back 19.5m (1.5 times the
to bushfire risk; and hazard within the lot; predominant height of the
b) maximise the protection f and mature tree canopy).
people and property during ii) to achieve setbacks
the passage of a fire front. from hazardous However a minimum separation
vegetation of 1.5times distance of 13m is considered
the predominant appropriate for the site based on
mature tree canopy the following:
height or 10m
whichever is the Construction of buildings
greater: and will be in accordance with
iii) 10m from any BAL-29 to minimise potential
retained vegetation impact from bushfire;
strips or small areas of
vegetation; and The proposed layout
iv) so that the elements provides for a direct access
of the development route for evacuation of the site
least susceptible to fire to Resort Drive;
are sited closest to the
bushfire hazard; It is understood that the
b) on lots 2500m2 or less applicant is required to install
– to maximise setbacks eight (8) fire hydrants as part
from hazardous of the development of this site
vegetation. and Precinct F (the adjoining
Lot 7). A bond of $189,000.00
is being held by Council for
this purpose; and
Resort Drive will facilitate
safe evacuation from the site if
required, as this road is
bordered by the golf course to
the west and leads away from
hazardous vegetation.
A Bushfire Management
and Evacuation Plan has been
prepared for the site.
AA1345BFIRE Rev. 2 Page 2 of 3
April 2016
JS/js
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.