Skip to the record
The gold standard in government transparency.

Council archive · source document

ASTP TP Report · MCU24/0001

of 15

Text shows just the words. Original shows the document exactly as it was published.

     •    Pergolas, landscaping, fencing and architectural design of balconies are used to mitigate views
          to/from the private open space onsite and to/from adjoining premises (AO20.5);
     •    All mechanical plant will be screened from street view and adjoining premises (AO21.3);
     •    Bins will be stored behind private open space fencing and raised garden beds, such that they will
          be screened from the street (condition to comply) (AO21.41); and,
     •    Earthworks onsite will not result in a change to the natural ground level of more than 1.5 metres
          (AO22.1).

The propsoed Dual Occupancy development does not comply with the following Acceptbale Outcomes of
the Zone Code:
    •    AO12.1 – reduced front setback, reduced southern side setback and reduced eastern side setback
    •    AO12.2 – swimming pool within 2m of northern front boundary
    •    AO17.1 – fence on the front boundary that does not step in at maximum 5 metre intervals
    •    AO17.2 – solid front fence sections exceeding 1.2 metres high
    •    AO17.4 – landscaping not provided between front fence and front boundary (fence on boundary)

The proposed development is considered to comply with the corresponding Performance Outcomes of
the abovementioned benchmarks, as demonstrated below within Table 2 below.


Table 2 Code Assessment against the specific areas of non-compliance - Medium Density Residential Zone Code
 Performance Outcome                                   Acceptable Outcomes
 Building Setback                                      AO12.1
 PO12                                                  Buildings and structures meet the following
 Buildings and structures are designed and sited       minimum boundary setbacks:
 to:                                                        (a) for frontages — 6 metres
      (a) provide a high level of amenity to users          (b) for side boundaries—
          of the subject site and adjoining                         i. 1.5 metres setback up to 4.5 metres
          premises, including provision of visual                       height;
          and acoustic privacy;                                    ii. 2 metres setback between 4.5
      (b) not unreasonably obstruct views or                            metres and 7.5 metres height; and
          cause overlooking of private open                       iii. 2.5 metres where above 7.5 metres
          space or habitable areas of adjoining                         height
          premises;                                         (c) for the rear boundary 6 metres
      (c) provide adequate distance from
          adjoining land uses;                         AO12.2
      (d) preserve existing vegetation that will       The front 6 metres of the property is landscaped
          help buffer development;                     open space, provided that uncovered visitor
      (e) allow for space and landscaping to be        parking, or swimming pools protruding no more
          provided between buildings including         than 1 metre above the ground level, can be as
          adequate area at ground level for            close as 2 metres from the front boundary.
          landscaping with trees, shrubs,
          outdoor living and utilities;                AO12.3
      (f) be consistent with the predominant           N/A to proposal.
          character of the surrounding area; and
      (g) protect the natural character and            AO12.4
          avoid adverse impacts on ecologically        N/A to subject site.
          important areas such as national
          parks, waterways and wetlands.


ASTP Ref: 230904                                                                                     Page 9 of 15

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

ASTP TP Report.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.