Department of Infrastructure, Local Government and Planning

Asite plan drawn to an appropriate scale (1:100, 1:200 or Confirmed wv -  .
1:500 are recommended scales) which shows the following: Emai

* the location and site area of the land to which the
application relates (relevant land)

* the north point

* the boundaries of the relevant land

* the allotment layout showing existing lots, any proposed
lots (including the dimensions of those lots), existing or
proposed road reserves, building envelopes and
existing or proposed open space (note: numbering is
required for all lots)

* any existing or proposed easements on the relevant
land and their function

* any access limitation strips

* all existing and proposed roads and access points on
the relevant land.

A statement about how the proposed development Confirmed

addresses the local government's planning schemes and

any other planning documents relevant to the application. NA

A statement addressing the relevant part(s) of the State Confirmed

Development Assessment Provisions (SDAP). Not
applicable

Applications for building work (including extensions and demolition that is
assessable development)

Floor plans drawn to an appropriate scale (1:50, 1:100 or Confirmed
1:200 are recommended scales) which show the following: | Not y~

* the north point applicable
* the intended use of each area on the floor plan (for
commercial, industrial or mixed use developments only)
* the room layout (for residential development only) with
all rooms clearly labelled
* the existing and the proposed built form (for extensions
only)
* the gross floor area of each proposed floor area.

Elevations drawn to an appropriate scale (1:100, 1:200 or Confirmed
1:500 are recommended scales) which show plans of all Not
building elevations and facades, clearly labelled to identify applicable

orientation (e.g. north elevation).
+

Plans showing the size, location, proposed site cover, Confirmed

proposed maximum number of storeys, and proposed Not.

maximum height above natural ground level of the applicable

proposed new building work.

Plans showing the extent of any demolition that is Confirmed

assessable development. Not
applicable

Applications for operational work involving earthworks (filling and excavating)

IDAS form 6

Used in these records

About this file

File size
4.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

IDAS form 6 - 61 Morinda Circuit Noosaville.pdf · 4.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.