Council archive · source document
IDAS form 6 - 61 Morinda Circuit Noosaville · OPW16/0220
Attached to the e-mail Operational works application OPW16/0220.
Department of Infrastructure, Local Government and Planning Drawings showing: Confirmed 7 - ° existing and proposed contours Not. * areas to be cut and filled applicable * the location and level of any permanent survey marks or reference stations used as datum for the works * the location of any proposed retaining walls on the relevant land and their height * the defined flood level (if applicable) ¢ the fill level (if applicable). Applications for operational work involving roadworks Drawings showing: Confirmed * existing and proposed contours Not applicable * the centreline or construction line showing chainages, bearings, offsets if the construction line is not the centreline of the road and all intersection points * information for each curve including tangent point chainages and offsets, curve radii, arc length, tangent length, superelevation (if applicable) and curve widening (if applicable) ¢ kerb lines including kerb radii (where not parallel to centreline) and tangent point changes (where not parallel to centreline) * edge of pavement where kerb is not constructed * position and extent of channelisation * location and details of all traffic signs, guideposts, guardrail and other street furniture * pavement markings including details on raised pavement markers catchpit, manhole and pipeline locations drainage details (if applicable) cross road drainage culverts (if applicable) concrete footpaths and cycle paths location and details for access points, ramps and invert crossings * changes in surfacing material. Applications for operational work involving stormwater drainage Drawings showing: Confirmed * existing and proposed contours Not * drainage locations, diameters and class of pipe, open _—PPlicable drains and easements * manhole location, chainage and offset or coordinates and inlet and outlet invert levels * inlet pit locations, chainage and offset or coordinates and invert and kerb levels. Applications for operational work involving water reticulation | ‘ IDAS form 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
IDAS form 6 - 61 Morinda Circuit Noosaville.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.