                                                Facsimile Transmission
                                       File No:     2008/0658
                                       Date:        9 May 2008
                                       Fax No:      07 5449 9494
To:                    Tod Consulting Pty Ltd
Attention:             Phil McGrath – Your Ref: PM:AS 06583-5
From                   Kevin Slender, Technical Assessment Officer
Phone No:              07 5449 5216               Fax No: 07 54471062
Re:                    Development Permit for Operational Works for
                       Gateway Rise Pty Ltd (Bunnings Properties Pty Ltd)
                       Gateway Drive and Venture Drive Noosaville

Information Request


The following items require attention in order to progress the assessment of this
application:


   1. Please provide a pram ramp on the northern kerb of Venture Drive in line with the
      pram ramp shown on the southern kerb on Drawing 06583/11.
   2. Please note that proposed names of new roads, etc, are to be provided prior to the
      issuance of a Development Permit for Operational Works (Condition 20, Decision
      Notice 2007/1626 dated 13 Dec 2007).
   3. Please provide a concrete path 2m wide (and appropriate pram ramps) to the southern
      side of Venture Drive and to the Gateway Drive frontage of the site. (Condition 22,
      Decision Notice 2007/1626 dated 13 Dec 2007).
   4. Please provide details of the methods proposed for controlling erosion and sediment
      during construction. (Conditions 39 and 40, Decision Notice 2007/1626 dated 13 Dec
      2007).
   5. Please note that the bond referred to in Conditions 49 of Decision Notice 2007/1626
      dated 13 Dec 2007 will need to be received by Council prior to the issuance of a
      Development Permit for Operational works.
   6. Please confirm that the roadway flow widths (against the kerb and channel) within the
      proposed development are in accordance with Queensland Urban Drainage Manual. If
      not, please provide additional catch pits to comply with the requirements of QUDM.
   7. Please prepare a Construction Environmental Management Plan for approval by
      Council. (Condition 50, Decision Notice 2007/1626 dated 13 Dec 2007).
   8. WATER and SEWERAGE requirements:
          A. All references to NSC on drawings to be replaced with Sunshine Coast
              Regional Council (SCRC).
                                 IMPORTANT  AND LEGAL PRIVILEGE NOTICE:
    The information contained in this facsimile message is CONFIDENTAL and may be subject to legal privilege. If you are not
     the intended recipient, you are notified that any use of this message is prohibited. If you received this message in error,
                         please notify us immediately by telephoning 07 54495200 and destroy the original.
       Page:                    1 of 2
       Original to follow:      No
       Sunshine Coast Regional Council Tewantin Office            9 Pelican Street TEWANTIN (PO Box 141 TEWANTIN 4565)
       Ph 07 5449 5200          Fax 07 5447 1062
Full text of the other 1 page

Page 2

             B. Water main in road 1 to be extended from Lot 4/5 boundary along southern
                side of road to Lot 3 boundary to facilitate connection to possible future
                development of abutting allotment. Road crossing (2) to be deleted.
             C. Sewerage design adjacent to proposed retaining walls where sewer invert is
                below bottom of wall is not acceptable (i.e. Sewer Line 6). Please discuss
                options to modify design to suit council requirement with Council’s Water
                Supply and Sewerage Works Manager, Northern Division, Mike Froude
                (phone 5449 5288) prior to submitting amended drawings.
             D. All HCB’s to be specified as 150mm diameter and be 1.5m deep.
             E. Sewer lines 13 and 14 to be regraded to provide for 1.5m HCB depth.
             F. Note 3 to be amended to refer to “Council” in lieu of “Shire Engineer”.
             G. All notes to replace reference to NSC with SCRC.




Kevin Slender
Technical Assessment Officer




                                 IMPORTANT  AND LEGAL PRIVILEGE NOTICE:
    The information contained in this facsimile message is CONFIDENTAL and may be subject to legal privilege. If you are not
     the intended recipient, you are notified that any use of this message is prohibited. If you received this message in error,
                         please notify us immediately by telephoning 07 54495200 and destroy the original.
       Page:                    2 of 2
       Original to follow:      No
       Sunshine Coast Regional Council Tewantin Office            9 Pelican Street TEWANTIN (PO Box 141 TEWANTIN 4565)
       Ph 07 5449 5200          Fax 07 5447 1062

Used in these records

About this file

File size
34 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Information Request [As Published].pdf · 34 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.