Appendix F - Council Report - Change Application 28.2.19 · 51997.2302.01
Attached to the e-mail Change to DA Condition 4 (Cover over Restaurant) - 51997.2302.01.
Noosa Council documents
Town Planning Consent Permit - 11893 TC Page 8
Building Department
41. Submission to and approval by Council of building plans in accordance with the
Building Act, Council’s By-laws and Policies, the conditions of this approval and
substantially in accordance with plans drawn by Goodwin & Southwell Architects
numbered 96/5/201-206 dated September, 1998 and the Shire of Noosa Planning
Scheme apart from where amendments are required or dispensations have been granted
in conjunction with this approval.
42. Construction work and other associated activities are permitted only during the hours of
7.00 a.m. to 6.00 p.m. Monday to Saturday. No work is permitted on public holidays,
except where extended hours are approved by the Building Surveyor.
43. Access for people with disabilities is required to comply with the requirements of Part
D3 of the Building Code of Australia 1996. The developer is to provide the required
number of units to be accessible and fitted out for use by people with disabilities.
Disabled access requirements must also be provided to the carparking access, access
from the road to the main entry foyer, access to the restaurant and other facilities
provided for use of the occupants.
44. Toilet facilities for use by staff and the public are to comply with the requirements of
the Building Code of Australia 1996. Restaurant facilities appear to be deficient and it
is also necessary to identify staff facilities for the restaurant.
45. Fire protection including the provision of on site fire hydrants, fire hose reels, smoke
detection and alarms, etc are to comply with the requirements of the Building Code of
Australia 1996.
46. Exit lighting and emergency lighting are to comply with the requirements of the
Building Code of Australia 1996.
47. The pool is to be isolated from the building with a complying pool safety fence.
48. Ventilation of the carpark basement is to comply with the requirements of the Building
Code of Australia 1996.
49. The developer is to install adequate protection including hoardings, if required, for
members of the public using the adjoining walkway to the west during construction to
the satisfaction of the Building Surveyor. Such protection shall also include adequate
protection to adjoining property.
50. The final design of the kitchen space of the proposed restaurant, shall be undertaken in
consultation with Council’s Chief Environmental Health Officer. The developer shall
comply with the reasonable requirements of the Chief Environmental Health Officer.
51. The restaurant approved on the site shall have a maximum of 100 diners/patrons.
c:\users\noo.ecm.prod.web.svc\appdata\local\temp\4894c4ec-8cdd-4444-be14-b0cba2d65697.doc
Print Date: 10 December 2018, 9:45 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix F - Council Report - Change Application 28.2.19.pdfRelated documentApplication case desk ↗
About this file
- File size
- 494 KB (small file)
- File type
No other editions are linked here.