GENERAL NOTES
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, OLD, SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS
DIMENSIONS TAKE PRECEDENCE OVER SCALE
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS
-252.H
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS 8 ALL RELEVANT AUSTRALIAN
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
Bi-fold doors by CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
cabinet maker MAX BUILDING HT ABOVE NATURAL GROUND UNE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
Laundry underneath REQUIREMENTS
staircase
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
FLOORS AND TILED FLOORS ¦ REFER STRUCTURAL ENG DRAWINGS
FOR MEMBER SIZES
LEGEND
AIR CONDITIONING AS SPEC. ¦ INSTALLED
BY CONTRACTOR
450 X450 REMOVABLE ACCESS
PANEL - LOCATION TO BE CONFIRMED ON SITE
CONC. BLOCK WALL TO STRUCTURAL ENG.
DETAIL - RENDER AND PAINT AS SPEC.
COLORBOND FLASHING TO DETAIL
CLADDING CONTROL JOINT - REFER ELEVATIONS
CONCRETE SLAB TO ENG. DETAIL
CUPBOARD
90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
CLOTHES DRYER
DISHWASHER
COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EXISTING GROUNDLINE
REFRIGERATOR
FLOOR WASTE
S.S GRATED DRAIN AS SPEC.
HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HOT PLATES AS SPEC.
Enclosed stairwell HOT WATER
MECHANICAL RISER
MICROWAVE
1^15 2%_ 1760 ?50 l LZ25 2% NATURAL GROUND LINE
OVEN
PANTRY
-250^ ssik 1 480 ?50| .| PROPOSED GROUNDUNE
POUSHED TIMBER FLOOR AS SPEC
RHSTO STRUCTURAL ENG. DETAIL
•WIRILY BIRD* OR SIM. APPROVED
SINK
HARDWIRED SMOKE DETECTOR TO
COMPLY WITH AS. 3786-1993
SHOWER TO DETAIL
SHSTO STRUCTURAL ENG, DETAIL
SKYLIGHT AS SPEC.
NOOSA COUNCIL TUB
INTERNAL TILE AS SPEC,
APPROVED PLANS EXTERNAL TILE AS SPEC.
HWD TIMBER DECKING AS SPEC
TOP OF WALL
MCU14/0008 26 JUN 2014 IN-BUILT VACUUM SYSTEM AS SPEC
VANITY BASIN
TOILET SUITE
COLORBOND WALL FLASHING
06.12.1 hsBmlnoY CBoiil Apinovcl
PEREGIAN BEACH VILLAS Clloni Slgnlluro Approval;
ALEX CHARLWOOD
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, OLD, E 20.01.1 Ctanl loquoit anionclmenls
Dalo;
NOTES:
TBC BSB No.; 1043429