Attachment 2 - Sealed Final Judgment
Attached to the e-mail Pre-Request Response Application - MCU14/0008.03.
The original of this document is very large (19.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
GENERAL NOTES
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
PEREG1AN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, OLD, SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS
-252+H
90..j. 1.300 90,j. ^50_ f ^50 90V|. 1.300 90|.l
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
' AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS S ALL RELEVANT AUSTRALIAN
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
REQUIREMENTS
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
External staircase FOR MEMBER SIZES
LEGEND
AIR CONDITIONING AS SPEC - INSTALLED
BY CONTRACTOR
450 X450 REMOVABLE ACCESS
PANEL - LOCATION TO BE CONFIRMED ON SITE
CONC. BLOCK WALL TO STRUCTURAL ENG
DETAIL - RENDER AND PAINT AS SPEC.
COLORBOND FLASHING TO DETAIL
CLADDING CONTROL JOINT - REFER ELEVATIONS
CONCRETE SLAB TO ENG. DETAIL
CUPBOARD
90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
CLOTHES DRYER
DISHWASHER
COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EXISTING GROUNDLINE
REFRIGERATOR
FLOOR WASTE
S.S GRATED DRAIN AS SPEC
HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HOT PLATES AS SPEC.
HOT WATER
MECHANICAL RISER
MICROWAVE
NATURAL GROUND LINE
250 2.845 OVEN
|,480|, 910 ||50 2,845 901,|. 900 (. L 1.000 1.(50 3,780 250 f ^ 900 ^O 90 ^ 910 1.480 L PANTRY
PROPOSED GROUNDLINE
POUSHED TIMBER FLOOR AS SPEC.
+ ^ 250,. j. 4.870 750. .. 5315 RHS TO STRUCTURAL ENG. DETAIL
•WIRILY BIRD* OR SIM. APPROVED
SINK
HARDWIRED SMOKE DETECTOR TO
COMPLY WITH AS. 3786-1993
SHOWER TO DETAIL
SHS TO STRUCTURAL ENG, DETAIL
SKYLIGHT AS SPEC,
NOOSA COUNCIL TUB
INTERNAL TILE AS SPEC.
EXTERNAL TILE AS SPEC
APPROVED PLANS HWD TIMBER DECKING AS SPEC.
TOP OF WALL
IV1CU14/0008 26 JUN 2014 IN-BUILT VACUUM SYSTEM AS SPEC,
VANITY BASIN
TOILET SUITE
COLORBOND WALL FLASHING
WASHING MACHINE
Cllonl Slgnlluro Approval:
PEREGIAN BEACH VILLAS Cllonl Inllloli: ALEX C
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Dat«:
TBC PH; 0410 ISO 745
BSB No.: 1043424
ABN: S» 980 573 352