17. David Low Way must be upgraded for the length of its frontage to the subject site. The
     works must be undertaken in accordance with an Operational Works approval and must
     include in particular:
     (a) construction of a pedestrian footpath in accordance with the conditions of this
           Decision Notice
     (b) reinstatement of the footpath and verge area to match the balance of the site
           frontage, including the provision of topsoil and turf where the existing verge is
             disturbed.
Site Access and Driveways
18. A sealed access driveway must be provided from David Low Way to all parking and
     maneuvering areas of the development. The works must be undertaken in accordance
     with an Operational Works approval and must include in particular:
     (a) a driveway crossover in accordance with IPWEAQ standard drawing SEQ R-051
     (b) suitable safety measures, including warning signage, to improve driver awareness of
           pedestrians and enhance pedestrian safety
19. The internal driveway must be designed and constructed with widths, crossfalls and
     gradients in accordance with Australian Standard AS/NZS 2890.1:2004 - Parking
     Facilities.
Car Parking
20. A minimum of 12 car parking spaces must be provided and marked on the site. The works
      must be undertaken in accordance with an Operational Works approval and must include
     in particular:
     (a) 3 visitor parking spaces within the total, which are clearly marked for that purpose
             and accessible at all times for visitor use
     (b) crossfalls and gradients in accordance with Australian Standard AS/NZS
           2890.1:2004 - Parking Facilities
     (c) garages, including door openings, in accordance with section 5.4 of Australian
             Standard AS/NZS 2890.1:2004 - Parking Facilities
Pedestrian
21. Pedestrian facilities must be provided for the development. The works must be
     undertaken in accordance with an Operational Works approval and must include in
     particular a 2 metre wide concrete footpath within the road verge for the entire length of
     the site's frontage to David Low Way.
Stormwater Drainage
22. The site must be provided with a stormwater drainage system connecting to a lawful point
     of discharge. The works must be:
     (a) generally in accordance with drawing number 17011-SW1 B prepared by SCG
           Consulting Engineers
     (b) undertaken in accordance with an Operational Works approval.
Electricity and Telecommunication Services




   Page 6 of 36
Log in to download the original file

Attachment 2 - Sealed Final Judgment.pdf · 19.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.