      In this regard the development should have a Minimum Floor Height of RL 2.6 (AHD) and
      garages should have a Minimum Floor Height of RL 2.3 (AHD). These levels however are
      subject to change and verification shall be made to Council’s Land Development Section prior
      to obtaining a Development Permit for Building Works.

      The applicant should note that compliance with these levels does not necessarily require the
      whole site to be filled. To this extent excessive filling should be avoided to prevent any
      impacts on neighbouring properties and minimum floor levels should be strictly adhered to
      without building higher than is actually needed to prevent flooding.

Vehicle Access and Carparking Areas
17.   Concrete access and carparking areas shall be provided generally in accordance with drawing
      number 0885 SK01 dated Jan 2008 by Greg Gibbs Architects.
18.   The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for
      user class 1A with allowance for vehicles to enter and leave the site in a forward gear and with
      a minimum head clearance (headroom) at any point of 2.2m.
19.   The driveway shall be designed and constructed to Council’s design standards and to grades
      that prevent vehicles from scraping and/or bottoming whilst also allowing pedestrians
      movements along the footpath without any step or level difference. Should any driveways be
      constructed to grades that do not comply with AS2890.1-2004, Council will require that the
      driveway be removed and reconstructed to levels that do comply.
      Please note, a step between the driveway and the footpath shall be avoided, as it is preferred
      to have the footpath continue at a constant grade to minimise the potential for pedestrians to
      trip or fall. A Development Permit for Operational Works shall be required.
20.   To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath,
      the driveway and any associated fencing or vegetation near the driveway shall comply with the
      minimum sight line requirements as defined in AS2890.1, section 3.2.4. The applicant shall
      demonstrate compliance by illustrating these sight lines on the plans submitted for both
      Operational Works approval and Building Works approval.
Frontage Works
21.   Footpath improvements such as topsoiling, grassing, and tree planting are required to the
      Robert Street frontage of the site in accordance with Planning Scheme Policy PSP03
      Landscaping Plants & Guidelines. Grass shall be couch, free of weeds.
22.   A new 1.5m wide concrete footpath shall be constructed along the Bluefin Court frontage of
      the site in accordance with Council’s design standards and to an alignment that protects any
      significant vegetation or any underground services.
23.   All footpaths, driveways and parking areas shall be designed and constructed to ensure
      pedestrian safety using non-slip materials, to produce an evenly graded surface finish, and to
      be in accordance with the Disability Discrimination Act 1992 and Australian Standard 1428.1
      Design for Access & Mobility.
Roof Water & Stormwater Drainage
24.   Roof runoff from any new dwelling unit shall be directed to a rainwater storage system or tank
      (minimum storage 5000 litres per dwelling unit) that is installed to ensure water from the tank
      is used for external uses (such as watering gardens, irrigation, ornamental ponds, water
      features, topping-up swimming pools, outdoor cleaning, etc) and for use in flushing of toilets
      internal to the dwelling. All rainwater tanks are to be designed and installed in accordance with
      the Queensland Development Code (QDC), Part 25 – Rainwater Tanks, and shall be part of
      the plumbing application in conjunction with the building approval. The location and capacity
      of the tanks shall be clearly shown on the plans submitted for Building Works and Operational
      Works approvals and any overflow shall be directed to the road frontage or the stormwater
      drainage system located at Robert Street.

                                                                                          3 of 10

Used in these records

About this file

File size
68 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - Advice Agency (Energex) 010.2008.00000203.001 [As Published].pdf · 68 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.