DBW Application - 30 Upper Pinbarren Creek Rd Pinbarren
GENERAL NOTES
aluminium framed^indows + doors TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP10/MGP12
4. HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
timber posts 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
o SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7. LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
co horizontal cladding fixed as per manufacturers specifications + . TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
CM material selection as per aus standards Elevation 1 - a BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
IT AS NO RESPONSIBILITY WILL BE TAKEN AFTER
OS CONSTRUCTION HAS COMMENCED
— 11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
..
I HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PERAS
CD 3660.1.2000
rn' T , T
ZTZ DOMESTIC SMOKE ALARMS
EZI
CU 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
Elevation 2 - a 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
CD 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
©INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
8
Si 8
111 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
^■1 TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
---------- - ---------
existing doors relocated existing water tank
ELECTRICAL AND ENERGY EFFICIENCY
Elevation 3 - a 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
colorbond sheet roofing fixed as per manufacturers specifications
DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION C/5
AND COMPLIANCE
— 05
----------- - --------
CD
existing 40m2 cottage existing window relocated CD
Elevation 4 - a
NOT FOR CONSTRUCTION Q
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
O
PROPOSED: CLIENT: BEATRICE + JOHN MARSHALL BUILDER: MANDY'S DRAFTING ONLY SHEET: 4 of 4 DATE:____ ISSUE NO:
RENOVATION PH: 5485 2904 + 0417 703 436 TBC PH: 0403 481 474 SCALE: 1:100 22 MAR 2023 BJ-2023-E
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH