Original source · versioned page text
DBW Application - 30 Upper Pinbarren Creek Rd Pinbarren
GENERAL NOTES
TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
Areas THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
Name Area AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
floor 80.05 m2
CTJ MGP 10/MGP12
Grand total 80.05 m2 04 of 04' 4. HARDW00D FRAMING TO BE MINIMUM STRESS
s 04 of 04' GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
Elevation 2 - a _o
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
LU
o 8
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
'■rr"-x 8 7. LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
□
006/
CU TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
bed bath § 9. BUILDER AND TRADES ARE TO CONFIRM ALL
§ I
existing line of walls V CM
(existing timber) --A----' MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
bed SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
(© (existing timber) S =^F= AS NO RESPONSIBILITY WILL BE TAKEN AFTER
3/82gg/slide
05 3*^ /obe
1 820
-I I
in
CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
11 870 } HER OWN WORK
o r Ssp
H'\
dr hil'di _n|//900 e=^F=
io
00
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
05 existing line <S S> / WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
of concrete sta<fk machine + dryer
linen WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
o REGULATION 2016
8
§
CO
I—I 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
i 'tfi I w
L2j WITH AS 1670.6 -1997 FIRE DETECTION, WARNING, CONTROL
/livincK o
S AND INTERCOM SYSTEMS.
CD (timber) o 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
IB T\
rafters
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
©INDICATES THE LOCATION OF WIRED SMOKE ALARMS
2«20
5 GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
■3
s. existing SUBJECT TO CONFIRMATION UPON SITE MEASURE
§ relocated
5615
1 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
§
co
PRIVACY OPTIONS
O
CO
ELECTRICAL AND ENERGY EFFICIENCY
8 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
ZP
04 of 04 S
■■s
2700 1215
| 820 | 910 I DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
2400 115
LU
AND COMPLIANCE
Elevation 3 - a
l!4of04
70 5875
10815
r
NOT FOR CONSTRUCTION CD
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
CD
PROPOSED: CLIENT: BEATRICE + JOHN MARSHALL BUILDER: MANDY’SJJRAFTING ONLY SHEET: 3 of 4 DATE: ISSUE NO:
RENOVATION PH: 5485 2904 + 0417 703 436 TBC PH: 0403 481 474 SCALE: 1:100 22 MAR 2023 BJ-2023-E
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (DBW Application - 30 Upper Pinbarren Creek Rd Pinbarren.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.