Council archive · source document
Attachment D - Proposed Primary Dwelling Building Plans · MCU22/0135
Plans and drawings: the text below has words only, no drawings.
Very large file (11.7 MB): may take a few minutes to open.
Colorbond Custom orb roof sheeting 600 600
fixed to manufacturers specification O/H O/H
for required wind category. (5° pitch).
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification. Approx. Extent of Skylights Behind
installed to manufacturers specification.
Min. 250(W) x 200(H) Recessed 5°
Curtain Track. Truss manufacturer to
make allowance in truss design. Prefabricated 700mm upstand pine roof
trusses at 900 crs. Roof Bracing to truss
Lightweight rendered cladding manufacturers specification.
over to builders detail.
Select Timber Cladding fixed to
Ceiling Height
A manufacturers specification.
Sunken Lounge Dining Ldy
2700
Joinery
2400
13 Wall Framing to Gyprock wall &
engineers specification. ceiling linings.
Approx. Existing
Ground Line.
Step Dn
360
Rendered 200 series built up Approx. Proposed
blockwork walls to engineers detail. Ground Line.
Reinforced footing & slab Stairs
to engineers details. 2 risers @ 180mm
1 treads @ 250mm
Compacted fill to
Polished Concrete Treads.
engineers detail.
SECTION A - 03
Scale : 1 : 100
Prefabricated 700mm upstand pine
roof trusses at 900 crs. Roof Bracing
to truss manufacturers specification.
Colorbond Custom orb roof sheeting
600
fixed to manufacturers specification
600 O/H for required wind category. (5° pitch).
5°
O/H Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
Wall Framing to
Ceiling Height
engineers specification.
Hers
2700
Joinery
2400
Gyprock wall &
ceiling linings.
300 High Glass Pool Edge
Approx. Existing
Ground Line. Pool
Approx. Proposed Nom 200 Thick Concrete Pool
Ground Line. Walls to engineers detail.
Reinforced footing & slab
to engineers details.
Rendered 200 series built up
blockwork walls to engineers detail.
SECTION B - 03
Scale : 1 : 100
Revision Schedule Project Address : Sheet Name: Project Status: Project Number:
Number Description Date Issued by No. 49 Donnellys Road, Ridgewood Sections WD 20-060
1 WD 20/01/20 BJH
Client Name : Project Issue Date : Q.B.C.C Lisence No. Sheet Number:
Email: [email protected]
Website: www.iconbuildingdesign.com.au Rhys & Monique 20/01/2021 126221 11
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment D - Proposed Primary Dwelling Building PlansRelated documentApplication case desk ↗
About this file
- File size
- 11.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.