Wall Framing to Rendered Brickwork.
engineers detail.
Provide cavity flashing
Prefabricated pine roof Colorbond Trimdek roof sheeting F.F.L. (Finished and weepholes at 960 crs
trusses at 900 crs to fixed to manufacturers specification Floor Level). to brick course below sills
truss manufacturers spec. for N3 wind loading. and finished floor line.
for N3 wind classification.
Termite Protection in accordance
Roof Battens to with relevant specifications.
engineers spec.
Vapour Barrier on
min. 50mm thick Rendered 200 series
bedding sand to built-up blockwork base
< 1200*
Colorbond fascia engineers spec. to engineers details.
and gutter.
Compacted
Wall Framing to
Square set ceilings in Provide truss upstand as required Granular Backfill.
engineers specification. F.G.L. (Finished Ground Line).
accordance with builders spec. in accordance with truss
Selected cladding fixed to manufacturers specification.
manufacturers specification.
Tie Down. Refer to Reinforced concrete slab &
engineers specification. footings to engineers details.
*
Gyprock wall &
Gyprock wall and ceiling linings.
*
2700 ceiling height
ceiling linings.
Wall Framing to BUILT - UP BLOCK BASE /
engineers specification. Rendered Brickwork.
BRICK VENEER WALL DETAIL
Tie Down to engineers spec. Termite Protection in accordance Scale 1 : 20
with relevant specification. * Refer to engineers detail.
2700 - Ceiling Height U.N.O.
F.F.L. (Finished Floor Level) Tie down rods. Refer to
Galvanised wall ties at engineers specification.
600 crs. horizontally &
225 min.
450 crs. vertically. Wall Framing to
engineers specification. Gyprock wall and
F.G.L. (Finished Ground Line) ceiling linings.
Selected cladding fixed to
manufacturers specification.
Vapour Barrier on Reinforced concrete slab &
*
Termite Protection in accordance
min. 50mm thick footings to engineers details.
2700 Ceiling
with relevant specifications.
bedding sand to
engineers spec. Termite Protection in accordance Tie Down to
* Provide cavity flashing with relevant specification. engineers spec.
and weepholes at 960 crs F.F.L. (Finished
Fall Floor Level)
F.F.L. (Finished Floor Level). to brick course below sills
TIMBER FRAME WALL DETAIL and finished floor line.
225 min.
Reinforced concrete slab &
Scale 1 : 20
footings to engineers details.
* Refer to engineers detail. F.G.L. (Finished Ground Line).
200 series built-up blockwork Vapour Barrier on
< 1200*
base to engineers details. min. 50mm thick
Vapour Barrier on min. 50mm thick Reinforced concrete slab & bedding sand to
*
bedding sand to engineers spec. footings to engineers details. engineers spec.
Compacted
* Granular backfill.
N.G.L. / F.G.L.
BRICK VENEER WALL DETAIL
*
Scale 1 : 20
* Refer to engineers detail.
*
BUILT - UP BLOCK BASE /
Revision Schedule Project Address : Sheet Name: Project Status: Project Number:
TIMBER FRAME WALL DETAIL
Scale 1 : 20
Number Description Date Issued by No. 49 Donnellys Road, Ridgewood Details WD 20-060 * Refer to engineers detail.
1 WD 20/01/20 BJH
Client Name : Project Issue Date : Q.B.C.C Lisence No. Sheet Number:
Email: [email protected]
Website: www.iconbuildingdesign.com.au Rhys & Monique 20/01/2021 126221 12
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment D - Proposed Primary Dwelling Building PlansRelated documentApplication case desk ↗
About this file
- File size
- 11.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.