37 Gibson Street Noosaville
ENVIRONMENTAL NOISE IMPACT ASSESSMENT
26906 R06 37 Gibson Rd Noosaville ENV
© TTM Consulting Pty Ltd 2010




6. NOISE CRITERIA
6.1. Onsite Activity Noise
6.1.1. External Noise Criteria
The noise criteria typically applied in the Sunshine Coast Regional Council is the Maroochy
Planning Scheme Policy No.7 Acoustic Environment Assessment and for fluctuating noise utilises
the comparison of like vs like parameters. The measurement procedure and determination of
potential annoyance from such sources must utilise the following procedures:

      a) The measurement descriptor that must be recorded with the noise source operating is
      LA10,adj,T for short time duration intermittent noise. Noise level to be adjusted for Tonality or
      Impulsiveness in accordance with AS1055.1

      b) The measurement descriptor that must be recorded with the noise source inoperative is
      LA10,adj,T for short time duration intermittent noise.


      c) The determination of the relevant noise emission and extent of limit exceedance for the
      sources from the two measured conditions require the difference between the noise source
      operating and the source inoperative.’


A noticeable deterioration is considered to be an increase of 3dB(A) above the acoustic
environment (noise source inoperative) of a ‘noise sensitive place’

Based on the above assessment requirements, the assessment criterion is detailed in Table 2
below.

                         Table 2: Onsite activity noise assessment criteria for residential receivers

                 Time Period                                        Criteria L10 dB(A)
             Day period 7am-6pm*                                             60
           Evening Period 6pm-10pm                                           54
            Night period 10pm-7am                  45 internal (Sleep disturbance criteria Section 6.1.2)
* The Saturday night period ends at 9am, with the corresponding Sunday daytime period
commencing at 9am.

6.1.2. Sleep Disturbance Criteria 10pm to 7am
A criterion for sleep disturbance under the EPP (Noise) is addressed in the User’s Guide to the
EPP, and states the following:

             ‘In the case of fluctuating noise, the maximum level is correlated to sleep disturbance,
            rather than the ambient level. For good sleep, maximum noise levels of 45dB(A) to
            50dB(A) should not be heard in a bedroom more than 10 to 15 times a night.

            ‘Where noise is continuous, the ambient level during the sleeping period should not
            exceed 30 – 35dB(A) indoors in a bedroom.’




Page 9
Log in to download the original file

MCU10_2083 Development Application part 2 - Attachment 6 - Noise Impact Assessment Report.pdf · 540 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.