Original source · versioned page text
MCU10/2083 Development Application part 2 - Attachment 6 - Noise Impact Assessment Report
Proposed Commercial Development 37 Gibson Street Noosaville ENVIRONMENTAL NOISE IMPACT ASSESSMENT 26906 R06 37 Gibson Rd Noosaville ENV © TTM Consulting Pty Ltd 2010 6.2. Mechanical Plant Noise In accordance with the Sunshine Coast Regional Council requirement for the application of the background creep policy, the following criteria shall apply that mechanical plant does not exceed the existing background noise levels by more than 0dB(A). Based upon measured background noise levels measured at the site, the following noise limits apply to mechanical plant when measured at the property boundary of affected residents. Table 3: Criteria for Residential Receivers. Time Period Criteria LA90 dB(A) Daytime 7am – 6pm 46 (LA90 + 0 dB(A)) Evening – time 6pm – 10pm 41 (LA90 + 0 dB(A)) Night time 10pm – 7am 35 internal (Sleep disturbance criteria Section 6.1.2) Refer to Appendix B for graphical representation of measured noise levels. The above levels are quoted as a measured level, not a component level; hence, all plant proposed must be included in assessment including correction for tonality. By designing plant noise to a measured level rather than a component level, the additive effect of multiple plant is taken into account. Page 10