Original source · versioned page text
Astp TP Report
Performance Outcome Acceptable Outcomes
an impediment for pedestrians using
the footpath AO17.4
N/A – proposal complies.
Response
A 1.8 metre high fence will be provided along the front boundary of the site to screen and secure the
private open space area of Unit 1. The front fencing outcome does not comply with AO17.1 of the Code
as the fence steps in at a maximum 5.2 metre interval in lieu of 5 metres. Further, the front fence does
not comply with AO17.2 of the Code as the solid stonewall section of the fence has a height of 1.8
metres. The remainder of the fencing has lengths not greater than 5 metres and comprises aluminium
battens to achieve minimum 50% transparency. The overall intent of the front fencing outcome is to
provide visual and acoustic privacy for the pool area of Unit 1.
This outcome is appropriate on the basis that the front landscape strip widens to 2 metres in front of
the 5.2 metre long section of front fencing, which is the 1.8 metre high solid stonewall. As shown on
the Landscape Plans in Appendix 2, this garden bed will comprise a combination of ground covers,
shrub species and a palm that is expected to be a mid-rise tree growing up to 6 metres wide at full
maturity. As such, the non-complying section of front fencing will be suitably screened by landscaping
such that it will not compromise the visual amenity of the streetscape.
The proposal complies in full with PO17 of the Code on the following basis:
• the front fencing comprises a combination of high-quality stonewall and aluminium battens
with landscaping provided in front, collectively providing visual interest and contributing to the
overall attractiveness of the streetscape;
• the subject site, adjoining properties and adjacent properties all provide 1.8 metre high solid
walls along the front boundary. Further, this outcome is common for properties in the wider
Coral Tree Avenue streetscape. As such, the proposed front fencing outcome is compatible
with the existing streetscape character;
• with sections of permeable batten fencing provided along the street frontage, the proposed
development will not interfere with the movement of surface stormwater. Further, the solid
section of fencing abuts a swimming pool, which will absorb any stormwater flows in this
location in any case. Please refer to the Stormwater Management Plan in Appendix 4 for detail
around quantity and quality stormwater control;
• the permeable sections of front fencing adjacent to the turfed backyard and alfresco of Unit 1
will support casual surveillance of the street from the subject site; and,
• a minimum 2 metre wide deep planted garden bed is provided in front of the solid fence section
to screen its presence in the streetscape. This garden bed does not encroach into the verge.
As demonstrated above, the development complies with all relevant elements of the Medium Density
Residential Zone Code and no further assessment against the Code is required.
ASTP Ref: 220417 Page 12 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original