               88.    All advertising signage shall accord with Council’s Local Law No. 16 - Control of Advertising.
                      To this end the applicant shall be permitted to erect 2 pylon signs at the entry points shown
                      on the approved site plan. Further, 1 pylon sign is permitted on the showroom site at the
                      centre of the frontage to the internal loop road.
                      Telecommunications
               89.    The provision of high-speed telecommunications infrastructure is required for the
                      development. Provision for full broad band capacity within the subject site to every tenable
                      area is to be provided that gives access to broadband infrastructure capable of providing at
                      least 150Mbit/s. Such capability is to be provided either by underground conduit or other low
                      visual impact method. The intra-site broadband infrastructure shall connect to a suitable
                      external broadband network.
                      Energy Efficiency
               90.    The applicant shall provide a report detailing what measures have been undertaken with the
                      detailed design of the development to implement the strategies suggested in the Noosa Shire
                      Business Centre Energy Efficiency Assessment Report prepared by Parsons Brinckerhoff
                      dated April 2003. Further the report will detail how the development proposal complies with
                      the energy efficiency conditions contained in this approval and will also examine the viability
                      of delivering at least one third of the Centre’s energy requirements through renewable energy
                      technology. The report is to be submitted prior to the issue of a development permit for
                      building works and shall be to the reasonable satisfaction of the Manager Land Use.
               91.    The design of building over 2,500m2 gross floor area shall meet the Performance Criteria of
                      the Brisbane City Council’s City Plan 2000 – Energy Efficient Code (in effect as at April 2003).
                      Design which meets the Acceptable Solutions of the Code shall be deemed to satisfy this
                      condition. Design which does not meet the Acceptable Solutions of that Code, but which
                      otherwise reasonably responds to the Performance Criteria using the alternative mechanism
                      provided in the Parsons Brinckerhoff (PB) report (April 2003), shall be deemed to satisfy this
                      condition. This requirement excludes retail speciality tenancies and display areas within the
                      showrooms.
               92.    The design of buildings less than 2,500m² gross floor area shall meet the Performance
                      Criteria set out in the “Design for Climate” Energy Efficiency Policy of the draft Gold Coast
                      City Planning Scheme (as at April 2003). Design which meets the Acceptable Solutions of
                      that policy shall be deemed to satisfy this condition. Design which does not meet the
                      Acceptable Solutions of that policy, but which otherwise reasonably responds to the
                      Performance Criteria using the alternative mechanism provided in the Parsons Brinckerhoff
                      report (April 2003), shall be deemed to satisfy this condition. This requirement excludes retail
                      speciality tenancies and display areas within the showrooms.
               93.    Use of lightweight building materials is to be maximised wherever practicable. Hythermal
                      mass external walls shall be insulated and/or shaded from direct sunlight. The use of pre-
                      cast concrete slabs is to be minimised where practicable.
               94.    The design of the evaporative cooling system shall seek to optimise energy efficiency by
                      identifying and maximising the advantage of the prevailing winds at the site.
               95.    Spectrally selective and/or low emissivity glass shall be incorporated where appropriate in
                      the detailed design, so as to reduce heat transmission to and from buildings.
               96.    Hot water requirements of the site are to be provided by solar powered hot water systems,
                      heat pumps, or heat recovered from refrigeration or air-conditioning systems subject to
                      compliance with relevant health regulations. Where it is demonstrated to be satisfactory by
                      the Manager – Environmental Services that such technology is impracticable, five star solar
                      gas hot water will be accepted as an alternative.
               97.    The developer shall seek to apply the energy efficiency strategies listed at Table 5.1 of the
                      Energy Efficiency Assessment report where appropriate in the detailed design of buildings.




                                                                                                      Page 17 of 40
Document Set ID: 24254301
Version: 4, Version Date: 29/10/2025
Log in to download the original file

Minor Change Existing Approval 132002.220285.I (As Published).pdf · 292 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.