120. For any medical center established on the site a clinical waste service is required for the
activities. The operator is required to arrange with a licensed clinical waste contractor for the
commencement of such service.
Trade Waste
121. The bin washing area is to be roofed and the floor is to fall to a bucket trap with the waste
pre-treated by a grease arrestor prior to discharge to the sewer. Rainwater is to be excluded
from the bin washing area. Bin washing is to take place only at the bin washing area.
122. Full truck access is to be provided to each grease arrestor and/or pre-treatment device for
cleaning and servicing. Where access is restricted, a pump out line is required.
123. Liquid waste generated by industry, small business and commercial enterprises is referred
to as Trade Waste.
124. Council approval must be gained prior to the discharge of Trade Waste to Council’s sewerage
system. Approval may be granted through the issuing of a Trade Waste Permit.
125. All Trade Waste requirements including pre-treatment devices must be shown on hydraulic
plans submitted to Council for approval.
126. Trade Waste requirements must be in place, inspected and approved prior to
commencement of trading or operation.
127. All trade waste pre-treatment devices must be easily accessible for servicing purposes.
Building Services
128. The applicant shall comply with the Disabled Discrimination Act (DDA) requirements in
relation to the installation of disabled access and the provision of disabled facilities, and
access to this building and the provision of sanitary facilities shall comply with the
requirements of Section D Part D3 and Section F Clause F2.4 of the Building Code of
Australia.
129. A Plan for equitable access for patrons of the development shall be prepared in consultation
with Council’s Equitable Access Reference Group prior to the issue of a development permit
for building works to the reasonable satisfaction of the Manager - Land Use.
General conditions
130. Any fencing provided in conjunction with the development is to be setback an average of two
(2) metres to any internal road frontage. Fencing shall not be installed within OS3.
131. Deleted.
132. Existing trees on the site and within road reserves are to be retained, except where removed
due to building operations or the conduct of the approved use. The landscape plans are to
denote areas of existing vegetation or existing trees to be retained. To this end, the design
of the internal loop road, pedestrian and cycleways, and swales within the development may
meander in order to facilitate the retention of any existing vegetation where practicable within
the proposed loop road area.
Security
133. Security in the form of a cash bond or trading bank guarantee to the sum of $500,000 must
be submitted, to secure performance of all conditions of this development permit, prior to the
issue of a development permit for operational works. If Council is required to draw against
this guarantee, the applicant will be required to ‘top up’ the guarantee until an amount of
$500,000 has been secured. The total amount of security required to be submitted to Council
shall not exceed $1,000,000. The cash bond or trading bank guarantee will be returned on
performance of the conditions of approval less any costs incurred by Council in respect of
enforcing this development permit.
Currency
134. This development permit lapses 4 years after the Development Permit takes effect.