                      Headworks
               205. Headworks contributions are required for Water Supply and Sewerage and will be charged
                    in accordance with Council’s Planning Policies, PSP 28 - Water Supply Headworks
                    Contributions and PSP30 - Sewerage Headworks Contributions. These headworks are to be
                    paid by the applicant prior to the issue of a Development Permit for Building Works. An
                    estimate only of the expected contribution is:-

                            Retail Centre                           $466,608.00

                            Showroom & Commercial/Business          $260,340.00

                                            TOTAL                   $726,948.00

                      General
               206. Prior to undertaking any excavation, the person acting on this permit shall contact public
                    utility service providers to ascertain the location of their underground services.
               207. The applicant shall sign a written undertaking to be responsible for the full cost of repairs to
                    road pavement, footpath, kerb and gutter, or other Council property and facilities damaged
                    as a result of construction of the proposed development.
               208. Where kerb and channel is constructed at a road intersection or any other place it is provided,
                    disabled access shall be incorporated.
               209. No Council property or facility shall be interfered with during works associated with this
                    development without Council approval.
               210. A Traffic Management Plan is to be prepared by a Registered Professional Engineer of
                    Queensland addressing safety during construction, including pedestrian safety, in
                    accordance with the Manual of Uniform Traffic Control Devices and Department of Transport
                    (Main Roads Division) Roadworks Signing Guide. A copy of which is to be submitted to
                    Council for their records prior to construction commencing.
               211. All designs for engineering works involving the construction of pavements, kerb and channel,
                    vehicular access, footpaths, turnouts, stormwater drainage, water supply or sewerage
                    reticulation shall be prepared in accordance with the requirements of Council's Engineering
                    Design Standards, shall reference where applicable to Council’s Standard Drawings and
                    shall incorporate best engineering practice.
               212. A suitably qualified Registered Professional Engineer shall prepare engineering drawings
                    and specifications for all engineering works, which shall be submitted in conjunction with an
                    application for a development permit for operational works.
               213. Any alteration of a public utility or other facility necessitated by the development of the land
                    or associated construction works either internal or external to the site
               214. Prior to commencement of the use, or a certificate of classification being issued (whichever
                    occurs first), a certificate shall be submitted to Council from a registered Professional Civil
                    Engineer of Queensland certifying that the operational works have been inspected and no
                    items have been identified that suggest the work has not been completed in a workmanlike
                    manner.
               215. As Constructed drawings certified by a registered surveyor and a registered Professional
                    Civil Engineer of Queensland showing the extent and finished levels of the filling works are
                    to be submitted for Council's records, prior to the use commencing.
                      These drawings must fully detail levels for all engineering works including water supply and
                      sewer reticulation, drainage structures, building floor levels, finished ground levels effluent
                      trenches and pavement surface levels. Drawings shall be on transparencies, a hard copy
                      highlighting any changes from design and in electronic format on an IBM PC compatible
                      floppy disk in a format capable of integration with Council’s computer system.



                                                                                                      Page 30 of 40
Document Set ID: 24254301
Version: 4, Version Date: 29/10/2025
Log in to download the original file

Minor Change Existing Approval 132002.220285.I (As Published).pdf · 292 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.