Skip to the record
Beware of cheap imitations.

Original source · versioned page text

Minor Change Existing Approval 132002.220285.I (As Published)

of 40

Page text shows just the words. Original shows the document exactly as it was published.

                       10 pm - 7 am             Background noise level plus 3 dB (A)
                       Period
                                                Noise Level at a Commercial Place measured as the Adjusted
                                                Maximum Sound Pressure Level
                                                LAmax adj, T


                       7 am - 10pm              Background noise level plus 10 db(A)

                       10 pm - 7 am             Background noise level plus 8 db (A)

                      Air
               2.     Where Petroleum products are to be transferred from a delivery vehicle to an underground
                      fuel storage tank, and where an installation receives collectively more than 520 kilolitres of
                      petroleum product during a twelve (12) month period, then the underground fuel tank and
                      delivery vehicle shall be fitted with “Vapour Recovery System” equipment. Such equipment
                      shall be installed in accordance with Australian Standard (AS) 1940, Australian Institute of
                      Petroleum (AIP) CP6-1986 and AIP CP4-1993.
               3.     The aboveground tank shall be fitted with a “pressure vacuum valve” on the atmospheric
                      vent. The pressure vacuum valve shall be set to closed when the pressure in the tank is
                      between the design operating maximum pressure and the design operating maximum
                      vacuum in accordance with AS 1692.
                      Wastewater and other Liquid Waste
               4.     Wastewater and other liquid waste shall be discharged to sewer or transported to an
                      approved hazardous waste facility. The licensee must comply with the conditions of a current
                      trade waste permit issued of the site and/or conditions of an approval to transport to an
                      approved hazardous waste facility.
               5.     Vehicle or equipment wash down shall not be conducted in a manner which may cause the
                      contamination of surface stormwater run-off.
               6.     Wastewater from car washing must not be directed to the stormwater and can only be
                      directed to sewer under the conditions of a trade waste permit.
               7.     Drainage from paved forecourt and areas on which a vehicle can stand while being fuelled
                      or transferring petroleum products, shall be directed by appropriate surface grading into
                      grated sumps, floor silt arrestors, floor basket arrestors, gutters and/or grated drains leading
                      to underground drainage systems dedicated only to stormwater runoff, which finally
                      discharge into stormwater drainage systems as approved by the local authority.
               8.     Uncontaminated stormwater from roofed areas and uncontaminated ground areas shall be
                      directed away from petroleum loading and dispensing areas.
               9.     Wastewater and other liquid waste shall not be discharged or released to waters.
               10.    Provision shall be made to contain any leakage/spillage and contaminated waste water from
                      above ground petroleum product storage tanks and package storage areas, and to prevent
                      it from contaminating surrounding soil and stormwater. As a minimum, spill control measure
                      shall be in accordance with AS 1940.
               11.    Drainage from tank and package store bunds and compounds must be manually controlled
                      so that all wastewater passes through treatment facilities before release to the environment.
                      Any valve controlling the drainage from a compound shall be located outside the bund. The
                      valve shall be of a type in which the distinction between open and closed positions is obvious
                      and shall be closed and locked at all times except when flow to the treatment facility is
                      authorised by management.
               12.    Provide a notice adjacent to the bund valve displaying the following:


                                                                                                      Page 36 of 40
Document Set ID: 24254301
Version: 4, Version Date: 29/10/2025
Log in to download the original file

Minor Change Existing Approval 132002.220285.I (As Published).pdf · 292 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.