Council archive · source document
Engineering plans · MCU22/0207
Plans and drawings: the text below has words only, no drawings.
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
LTD
boundary line
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
2400 3500 3500 600 THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
NOOSA OWN BUILD.
750 750
Land anchor
PROPOSED ALTERATIONS
FB2
FB2
FB2
FJ2
FJ1
refer detail
24 WESLEY COURT
FB1
Dia 315 concrete NOOSA HEADS
PP1
1500
FJ3
piles, refer detail
750
DRAWING TITLE
FOUNDATION & JETTY PLAN
600
existing doors
MEMBER SCHEDULE SCALES
FJ1 - 200 x 50 F14 CONTINUOUS JOISTS AT 500 CRS
frame
2-NO. SS framing anchors per connection
FJ2 - 200 x 50 F14 SINGLE SPAN JOISTS AT 250 CRS
2-NO. SS framing anchors per connection
FJ3 - 200 x 50 F14 SINGLE SPAN JOISTS AT 500 CRS
2-NO. SS framing anchors per connection
SURVEY DATUM
FB1 - 200 x 75 F14, 150 x 90 x 10 mm SS angle, 250 mm long
with 4-M12 to bearer, 2-M16 to top of pile .
FB2 - 200 x 75 F14, 150 x 90 x 10 mm SS angle, 250 mm long
with 4-M12 to bearer, 2-M16 to top of pile ASSOCIATED CONSULTANTS
PP1 - 200 x 50 F14 pole plate fixed with M12 at 900 CRS
boundary line
REVISION LIST
A ORIGINAL ISSUE 28/08/19
B
C
PF1 DETAIL
Computer File
220632FD.DWG
DRAWING NUMBER SHEET REV.
22-0632-F3 3 A
See the original