JETTY NOTES 300
Dia 315
NOTES
Design Wind Velocity 49 m/s
Berthing Velocity and Hydraulic Loadings 0.75 m/s
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
Live Load - 2.0kPa to Deck LTD
All work shall be carried out in accordance with
RPEQ 4928
the relevant Australian Standards OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
Timber LINDSAY CONSULTING PTY LTD AND IS FOR
uPVC Permanent THE SOLE USE OF THE CLIENT. NO PART
All Timberwork shall comply to AS1720 and be casing MAY BE USED IN PART OR WHOLE WITHOUT
F14 hardwood durability 1 or CCA treated. PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
Fasteners shall be Grade 304 Stainless Steel. CLIENT AND PROJECT DESCRIPTION
N12 at 200 CRS
Concrete Pile reinforcement NOOSA OWN BUILD.
6-Y20 for protected locations Bed Level
All Concrete work shall comply with AS3600 6-Y24 for exposed locations PROPOSED ALTERATIONS
10 mm Abelflex
24 WESLEY COURT
1200
Exposure Classification "C" or similar
Minimum Concrete Strength - 50 MPa at 80 slump NOOSA HEADS
Existing Revetment Wall
Poured, compacted and cured in accordance
with the Australian Standard.
30 mm minimum cover to all reinforcement DRAWING TITLE
with uPVC cover (i.e. piles) TYPICAL FOUNDATION
DETAILS
3000 MIN
BED LEVEL -4.00
Steel
All Steelwork shall comply with AS4100 and shall be SCALES
hot dipped galvanised.
All welds shall be 8 mm Fillet weld
Alumimum
All Alumimum shall be in accordance with AS1664 LAND ANCHOR DETAIL
SCALE 1:20
Alumimum shall be grade 6061 T6
All welds shall be 4 mm fillet welds using TYPICAL PILE CONNECTION DETAIL
Not to scale FILL SIDE NON-FILL SIDE SURVEY DATUM
Alloy 5356 filler.
Provide 2 Layers of alcor between aluminum Steel Column .
and concrete surfaces. NS
Provide 2 coats of zinc chromate between ASSOCIATED CONSULTANTS
stainless steel and aluminium surfaces Uncontrolled Fill
1500 mm MIN
Natural Surface
(undisturbed ground)
REVISION LIST
A ORIGINAL ISSUE 28/08/19
300 B
MIN
C
150
DIA 450 mm 150 SQ x 8mm
MIN Base plate
TYPICAL MAIN POST PAD FOOTING DETAIL - PF1 Computer File
DRAWING NUMBER
220632FD.DWG
SHEET REV.
Not to scale 22-0632-F4 4 A