The details of each bio-retention basin and bio-retention garden are shown below in Table 7-3.
Table 7-3 Bio-retention Basin and Bio-retention Garden Details
~ ~~ ~ ~~ ~ ~ ~
mm (JTIfi] nIDil (lITO ~ ’iMttJ~ ~
~ (Jml am)
~ ~
(Jm)
~ ~
~
Bio-retention Gardens
1_B_4 120 120 270 0.80 0.15 0.25 12.0
1_C_1 120 120 270 0.80 0.15 0.25 12.0
2_F_1 243 243 540 0.80 0.15 0.25 24.3
2_G_1 558 558 1240 0.80 0.15 0.25 55.8
Bio-retention Basins
1_B_1 110 110 350 0.60 0.30 1.00 11.0
1_B_5 75 75 280 0.60 0.30 1.00 7.5
1_D_1 370 370 720 0.80 0.30 1.00 37.0
1_E_1 270 270 630 0.80 0.30 1.00 27.0
3_H_3 180 180 460 0.60 0.30 1.00 18.0
3_H_4 180 180 460 0.60 0.30 1.00 18.0
3_1_1 350 350 690 0.60 0.30 1.00 35.0
3_1_2 260 260 620 0.60 0.30 1.00 26.0
3_1_3 300 300 680 0.60 0.30 1.00 30.0
Bio-retention/Detention Basins I
3_1_4 450 450 1640 0.60 0.30 1.50 45.0
3_1_5 100 100 530 0.60 0.30 1.50 10.0
4_L 400 400 1550 0.60 0.30 1.50 40.0
7.3.3 Bio-retention Swales
The bio-retention swales were set up using the Healthy Waterways MUSIC Modelling Guidelines. They were
set up as two treatment nodes in
series; a bio-retention node with no extended detention
depth and a
vegetated swale with a low flow bypass equal to the filter media treatment rate. The vegetated swale was
assumed to be half the actual length as recommended by the guidelines.
The same filter media details as for the bio-retention basins were used. The filter depth was typically
assumed to be 0.6 metres, but this can be made deeper if preferred to allow for the planting of trees.
The details of the MUSIC treatment nodes are shown in Table 7-4 and 7-5.
Northbrook Corporation Pty Ltd Version 2 29 November 2012
SMP_v2.docx Commercial in Confidence Page 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 9 of 37 Appendix 7 - Stormwater Management MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 52.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.